8
2. CONNECtING
2.1. Connecting Gas (EC.U.1.G.)
- First check the present gas sort/gas pressure you are about to use.
Then check if the device is equipped for connecting to this particular gas sort/gas
pressure: refer to data on the device. If the mentioned values do not match, replace
the device or adapt it by replacing low-setting controls and/or nozzles: see table
below. In the last case the data on the device have to be adjusted too.
- Check the burner function in the intermediate position. If necessary, adjust the
function with the low-setting control.
Contact the supplier where the (new) device was bought.
Have connections and modifications only done by qualified professionals.
2.3. table Gas sorts (EC.U.1.G.)
Category
I
2E
& I
2H
Natural gas
I
2ELL
& I
2L
Natural gas
I
3B/P
& I
3+
Butane / Propane
Gas sort
G-20 G-20 G-25 G-25
G-30
G-30
G-30
G-31
Connecting pressure/gas
pressure
20
mbar
25
mbar
20
mbar
25
mbar
30
mbar
36
mbar
50
mbar
37
mbar
Rated nominal load
with 1 burner (netto)
kW
3,02
kW
3,40
kW
2,90
kW
3,25
kW
2,1
kW
2,27
kW
2,72
kW
2,05
Gas consumption
with 1 burner
m
3
/h
0,325
m3/h
0,363
m
3
/h
0,361
m
3
/h
0,403
m
3
/h
0,064
m
3
/h
0,07
m
3
/h
0,082
m
3
/h
0,082
Manifold/nozzle
1,35 mm
1,53 mm
0,75 mm
Kleinstelschroef
1,75 mm
0,75 mm
Gas connection
1/2 “