10 Description of the object dictionary
2036h Open Loop Current Reduction Idle Time
Function
This object describes the time in milliseconds that the motor must be at a standstill before current
reduction is activated.
Object description
Index
2036
h
Object name
Open Loop Current Reduction Idle Time
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
000003E8
h
Firmware version
FIR-v1426
Change history
2037h Open Loop Current Reduction Value/factor
Function
This object describes the rms current to which the motor current is to be reduced if current reduction is
activated in open loop (bit 3 in 3202
h
= "1") and the motor is at a standstill.
Object description
Index
2037
h
Object name
Open Loop Current Reduction Value/factor
Object Code
VARIABLE
Data type
INTEGER32
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
FFFFFFCE
h
Firmware version
FIR-v1426
Change history
Description
h
greater than or equal to 0 and less than value 2031
Current is reduced to the value entered here. The value is in mA and interpreted as root mean
square.
Version: 1.0.1 / FIR-v1748