Radar tests are required to choose NSR-Series.
Tick Save Data to local on upper right if the interface. Target data will be saved in
Data file under NSM tool installation path.
10
● ●
Strobe Siren Connection
Note:
● Radar alarm output is I/O relay type, please choose the right model & type strobe
siren.
● When radar alarm output is set and saved, power on the radar, and connect the
siren to radar, even if there is no PC server connection, the radar still works to trigger
the siren for intrusion protection.
Strobe siren signal wires are to connect to radar alarm signal output, as the diagram
3-4:
3.3
Fig.3-4
11
● ●
Alarm Setting:
3.4
①
Radar login:
When all devices are powered on, log in to the web interface of the
radar by input radar IP address in browser. (default IP: 192.168.10.123) The user name
is admin and passcode is admin, as the diagram 3-5:
②
Alarm zone:
Define the alarm zone in alarm setting, operation as following:
Alarm-Alarm zone, choose a serial number in "select area", and choose "enable" in
"select type", and draw alarm zone, when zone drawn, then click "confirm", as
diagram 3-6:
Fig.3-5
Fig.3-6
③
Alarm timeline:
Choose a suitable timeline in alarm timeline setting, then click
"confirm" to save.
Millimeter Wave Radar
Millimeter Wave Radar