AB2 Operation
Operation Modes
Nanomotion Ltd.
14
3 AB2
Operation
3.1 Operation
Modes
The AB2 can be operated in one of the following operation modes:
•
Velocity (AC) Mode
, in which the motor is driven
continuously. This is the default mode.
•
Step Mode
, in which the driver output is turned OFF and
ON at hardware, predefined intervals, thus driving the motor
in discrete steps.
•
Gate Mode
, enables to drive the motor in low velocities in
open loop by turning the driver output ON and OFF in time
intervals defined by the user.
•
DC Mode,
in which the motor works as a piezo actuator,
enabling accurate positioning of a few nanometers.
Both Enable_In and Motor_Connected inputs must be active for the four
modes to operate.
3.1.1 Velocity (AC) Mode Operation
In this operation mode, the motor is driven continuously by applying the analog
command voltage (± 10 V) using a relevant interface device (joystick or motion
controller).
3.1.2 Step Mode operation
In this operation mode, the driver output to the motor is turned on and off for
fixed time intervals defined in the hardware as follows:
•
ON phase - 1/16 second
•
OFF phase - 0.5 second
The amplitude of the output corresponds to the analog command input value and
thus determines the speed of the motor.