![Nanomotion AB2 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/nanomotion/ab2/ab2_user-manual_705062018.webp)
Connections and I/O Settings
Cable Connections
Nanomotion Ltd.
10
2.3 Cable Connections
Connect the following groups of cables together, isolating each of the signals:
•
POWER SUPPLIES – use 22 AWG (or lower AWG) wires
for the power supplies. For noisy surroundings, it is
recommended to twist the ground line and the power line
together.
•
ANALOG COMMAND – a twisted shielded cable is
recommended.
•
DISCRETE INPUTS – These signals are not sensitive to
noise and can be grouped together in the same harness with
any of the other groups.
2.3.1 Shielding
Since the high motor voltage is induced on the cable shield, it is required to
ground the shield on both sides. Both the driver card and the motor should be
grounded to the infrastructure earth.
2.4 Motor
Connections
The “Motor Connected” signal is available only at the motor connector, where it
is shorted to ground (see Table 9). This ensures that unprotected motor pins will
not be exposed to high voltage when the motor is not connected.
If more than one motor is connected to the AB2 Driver Box, use a suitable
branch cable.
If the motor type or the number of motor elements is changed, consult
Nanomotion for the appropriate driver configuration changes that may be
required.