AB2 Driver Box User Manual
Connections and I/O Settings
11
2.4.1 Motor Cable Length
The maximum allowed total cable length connecting the AB2 to the motor(s) is
20 meters for the HR types and 10 meters for the ST.
NOTE:
Use Nanomotion standard cables. Branching is possible to two and
four identical motors. Branch cables must be of identical length, the
sum of which not exceeding the allowed total cable length.
Nanomotion can guarantee proper driver and motor performance
only when Nanomotion standard cables are used.
2.5 Opto-isolated
Inputs
The following inputs are opto-isolated and are activated by shorting them to
ground; See also Table 10:
•
Powering
♦
Emergency Stop.
Disables the AB2 output.
♦
Enable_In.
Should be activated before the motor can be run.
•
Mode Enabling
♦
Step_In.
Enables Step/Gate operation Modes.
♦
DC Mode.
Activates the DC mode of operation
.
•
Direction Restrictions
♦
Left SW
. Disables the motor motion to the left.
♦
Right SW
. Disables the motor motion to the right.
To control
logic
VCC
AB
4
VCC
User Voltage
Command Input
390
Ω
Jumper 3
1
Figure 7: Opto-Isolated Input Interface