heatless desiccant air dryer
5. service ‘d’ instructions - dew point sensor
replacing or recalibrating the dew point sensor - es models only (every 1 year or 6,000 hours)
1.
Ensure the dryer is shut down and fully depressurised before attempting any maintenance work.(See Page 8, section 4.1)
2.
Release the catch located on the right side of the shroud to open it (See Figure D.1.1)
Dew point
pipe
shroud
latch
Figure D.1.1