15
D3
heatless desiccant air dryer
4.1 service ‘C’ instructions - exhaust valves
replacing exhaust valves - (every 4 years or 24,000 hours)
If the exhaust valves are not intented to be serviced, continue to
page 13.
1.
Ensure the dryer is shut down and fully depressurised (See page 8,
section 4.1).
2.
remove the bottom cover attached by 3 screws.
3.
remove the 8 x M10 socket head cap screws and 8 x washers to
release the valve block from the bottom manifold (figure C.1).
4.
remove the co-axial valves from the valve orifice within the bottom
manifold and discard.
5.
lightly grease and insert the new inlet valves into the valve block
ensuring the flow direction arrow is pointing as shown and the
valve ridge details cover the spill port. (See figures C.1.1, and
C.1.2).
6.
Reassemble valve block to the bottom manifold (torque setting;
40Nm). Refer to page 19-20 and follow the correct tightening
sequence when replacing block.
7.
Refit the bottom cover.
8.
Start up the Dryer (page 8), or continue to complete service C
The spoill ports are 1.5mm
Ø
holes