Page 23
16. OTHER DRYER CHECKS & NON-SERVICEABLE ITEMS
DAILY CHECKS
Visual and functional check of the dryer should be carried out daily:
•
Check the dryer for any external damage.
Assess and eliminate any defects found.
•
If the red service light appears, the dryer must be serviced.
Contact the service department and request required service kit.
•
Remove any loose dust or dirt from the dryer; clean all surfaces that appear to have attracted unwanted
contaminants.
•
Check the dewpoint sensor display (where applicable). If the dew point is not achieved the dewpoint
reading on the display will alternate with “dewpoint alarm” every 5 seconds. The no-volt alarm will also
activate.
Contact the service department and request a product service.
MAINTENANCE GUIDELINES
•
Maintenance operations only to be conducted when the system has been shut down and fully
depressurized.
•
All connections must be undone with care, paying particular attention to the areas that become
pressurized.
•
Do not modify or adjust the control settings.
•
Only certified Norgren approved replacement parts to be used.
•
Always check all connections for leakage and secure seating.
•
Ensure all loose parts are removed or secured to the dryer before operation.
Содержание 2 Series
Страница 1: ...MAINTENANCE SERVICE MANUAL www n psi com BREATHING AIR PURIFIER SERIES 2...
Страница 2: ...Document Issued Created Checked Revision 17 110 0491 05 11 2015 N McFall B Austin 0...
Страница 21: ...Page 21 14 MANIFOLD TIGHTENING SEQUENCES 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Top manifold Bottom manifold...
Страница 26: ...Page 26 NOTES...
Страница 27: ......