© by N&W GLOBAL VENDING S.p.A.
18
06 2007 294-00
pRogRammiNg thE paRamEtERS
c
asH
This set of functions controls all parameters regarding
the payment systems and the sales prices.
s
electioN
prices
Four different prices can be set for each selection ac
-
cording to the programmed time bands for when the time
table option is set.
For each of the 4 time bands prices (0 to 65,535) can be
programmed globally (same price for all selections) or
for the single selections.
Should the majority of products be sold at the same
price, it will be convenient to set the price globally and
then change the figure of the selections with different
prices.
t
ime
baNDs
Four programmable time bands are provided for selling
products at different prices.
The time bands are programmable for beginning and
end time by hours (00 to 23) and minutes (00 to 59).
If the values for start and end of the time band are set to
00.00 the time period is disabled.
The reference time is kept by an internal clock, program
-
mable as:
day/month/year week-day 1-7
and then
hour/minutes/seconds.
c
oiN
mecHaNisms
It is possible to decide which of the payment system
protocols available are to be enabled for the functions.
The available payment systems are:
- Executive
- Validators
- BdV
- mdB
By selecting one of the systems it is possible to control
its functions.
e
xecUtive
The following payments systems are available for the
Executive system:
- standard
- Price Holding
- coges
- U-Key
v
aliDators
When the “Validator Lines” function (line programming)
of the “programming” menu is displayed, the value of the
6 validator coin lines, A to F, can be changed.
bDv
The BDV protocol menus are used for defining the fol
-
lowing functions:
type of vending
Setting the operating mode for multiple or single dis
-
pensing. With multiple dispensing, the change is not
automatically returned after a successful selection; how
-
ever the credit is available for further selections. When
pressing the coin return button, the available credit is
returned if its value is lower than the maximum change
value.
change control
This function enables/disables the return of credit if no
selections are made.
If enabled, this function allows the return of coins even if
the first selection was not dispensed.
If however a selection fails for any reason, the change
will be returned if requested.
maximum credit
This function is used to define the maximum accepted
credit.
maximum change
It is possible to set a limit to the total amount of change
returned by the coin mechanism when pressing the coin
return button or after a single dispensing serving.
Any credit exceeding the amount programmed with this
function will be cashed.
accepted coins
It is possible to define which, among the coins recog
-
nised by the validator, are to be accepted.
Check the label on the coin mechanism for the correct
coin to value matching, indicating the position of the
coins.
Non accepted coins
This function programs the rejection of coins when in
“exact amount” mode.
Check the label on the coin mechanism for the correct
coin to value matching, indicating the position of the
coins.
dispensing buttons
this function enables or not the buttons on the coin
mechanism used to release the coins in the change
return tubes.
TECH>
SET PARAMETERS
TECH>
CASH
�
�
Содержание Snakky RY
Страница 1: ...Installation Use and maintenance EN English Doc No H 294U 00 Edition 1 06 2007 Snakky Ry...
Страница 2: ......
Страница 4: ......
Страница 48: ...sx436901 N W GLOBALVENDING S P A...
Страница 49: ...Snakky...
Страница 50: ...by N W GLOBAL VENDING SpA NOTE...
Страница 52: ......