NanaWall CSW75 Скачать руководство пользователя страница 18

Nana Wall Systems, Inc.
100 Meadowcreek Drive #250
Corte Madera, CA 94925

800 873 5673
415 383 3148
Fax 415 383 0312

[email protected]
nanawall.com

©2023 Nana Wall Systems, Inc.

PAGE 4 OF 4

•  Variations in wood grain or color; Warp within the allowable warp tolerance for wood panels per ANSI/WDMA I.S. 

6-A-01; Warp that does not affect the normal functioning of the Product; Warpage on wood panels caused by leaving 
panels in the open position exposed to the elements or not engaging the locking points properly when in the closed 
position; Resin or sap bleeding from wood panels.

•  Panel shrinkage or expansion caused by change in weather; Expansion or bowing of aluminum units caused by 

exposure to sunlight or caused by temperature difference between interior and exterior panel surfaces.

•  Acts of God, falling objects, fire, accidents, external forces, extreme weather events, or other conditions beyond 

NanaWall’s control.

•  Gas fill or retention levels in insulated glass units. 

•  Field testing of Product; Performance of the Product in conformance to any published NanaWall testing results 

(e.g. air infiltration, water infiltration, structural loading, thermal and sound). Published test results measure the 
laboratory performance of a single sample of the product of a certain size, sill and configuration that may not 
be applicable to the Product being field tested. Performance during testing may vary depending upon handling, 
installation, use, maintenance, and time after installation. Field testing must be in compliance with AAMA 502, 
including water penetration testing at 2/3 of the pressure of applicable published test results.

•  Products or components not supplied by NanaWall; Products that have not been paid for in full; Products ordered in 

larger sizes or special configurations beyond NanaWall’s published specifications. Product with glass that is heavier 
than NanaWall specifications; Product that has been modified or altered in any manner.

NANAWALL LIMITED WARRANTY

Содержание CSW75

Страница 1: ...75 Folding Center Pivot Frameless System This manual is to be used by the installer for installation and is to be kept by the Owner for reference Replacement parts can be ordered directly through Nana...

Страница 2: ...ckness for the panels is based on the Glass Association of North America GANA recommended minimum glass thickness for fully tempered Interior butt glazed fixed glass panels The CSW75 system is shipped...

Страница 3: ...anel 1 folding center pivot panel Panel 2 folding center pivot panel Panel 3 folding center pivot panel Panel 4 folding center pivot panel Panel 5 single double action end panel with pivot box or sing...

Страница 4: ...taller than the total unit height depending on how level the support structure above is See Sheet 2 of the Installation Manual It is important that the opening be the correct size Product performance...

Страница 5: ...nd floor sockets in concrete slabs and wood the substrate should be a minimum of 4 thick these components should be fully embedded into the concrete or wood and the clear edge distance in concrete or...

Страница 6: ...ener spacing in the support structure within the opening depends on substrate material design windload pressures if exterior of project panel height and other requirements of the project All anchoring...

Страница 7: ...D Step B1 Check all the carriers on all the folding panels Make sure all the locking nuts are securely tight Do not make any adjustments on the carriers yet Step B2 Before inserting the panels remove...

Страница 8: ...ross the width of the opening and 23 mm 7 8 at the top If the gaps are not correct then adjust the upper track by removing or adding shims above the head track as needed The upper track has to be perf...

Страница 9: ...ing with pivot point the dimension for the center of the pivot axle to the adjacent edge of the panel end cap should be 1 11 16 43 mm plus the additional 3 16 4 mm for the gap to the wall Please check...

Страница 10: ...chisel out the concrete to recess the floor closer into the floor Make sure that the full underside of the box rests on a flush and level surface and fix it temporarily into place Then install the top...

Страница 11: ...oint of the pivot panel use suitable material to finally fix the floor closer in place Before you put on the cover for the floor closer make sure to measure how much to cut off to make it fit with the...

Страница 12: ...nt where the hinge part with hinge pin is located in your direction The panels fold together and you can push them gently from the side using both hands 4 Note that there is a carrier at each upper ce...

Страница 13: ...cally check for worn or damaged components and replace as soon as possible A unit with nonworking components will subject the other components to increased stress and lead to premature failure A unit...

Страница 14: ...s thickness and specifications will be needed Depending on the model widths of frameless all glass panels may not be equal Ask NanaWall for the glass dimensions Please note that glass is required to b...

Страница 15: ...ance For Coastal Salt Water and Other Extreme Environments included in the Owner s Manual for each Product and is available for review on NanaWall s website is properly implemented and documented An E...

Страница 16: ...ent part or product is not commercially practicable NanaWall may elect to refund the purchase price of the affected product in full satisfaction of its obligations Wood Wood components must be properl...

Страница 17: ...application storage handling modification or waterproofing Movement of surrounding substrates including deflection of the header of more than or any other stresses on product Improper installation fla...

Страница 18: ...tions beyond NanaWall s control Gas fill or retention levels in insulated glass units Field testing of Product Performance of the Product in conformance to any published NanaWall testing results e g a...

Страница 19: ...___________________________________ Project Address if different from above _____________________________________________________________ INSTALLATION Installer Name _______________________________ Ad...

Отзывы: