59
8B. SERVICES – To be conducted by a technician only –
Test mode
Troubleshooting
Assembly and disassembly of the machine
(5) Replacing the AMP PCB
WARNING
To prevent electric shock, accident or injury and to prevent damage to the electrical
z
z
circuitry of the machine, be sure to turn the power switch off before performing the
tasks described below.
z
The PCB can be easily damaged by static electricity. If the PCB is
handled by a person charged with static electricity, parts mounted
on the PCB can be damaged. Before touching the PCB, be sure to
remove static electricity from your body by touching a grounded
metal object.
Turn the power switch off. (See P. 17 “7-2-1 Turning the power switch on.”)
Remove the side service door. (See P. 36 “8A-1-2 Removing and attaching the
side service door.”)
Disconnect the two harness connectors and RCA plug.
Harness connectors
RCA plug
Phillips pan head screws
(M3 x 8)
Remove the three Phillips pan head screw (M3 x 8) with flat and spring washers
and remove the AMP PCB.
Attach the AMP PCB following the above steps in reverse.