![NAMCO PAC-MAN BATTLE ROYALE Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/namco/pac-man-battle-royale/pac-man-battle-royale_operation-manual_3175112050.webp)
48
8B. SERVICES – To be conducted by a technician only –
8B-3 Error display (for the technician)
z
If the error indication remains after the appropriate
countermeasures have been taken, set the Test switch to ON and
then to OFF to cancel the error indication.
Error code
Error indication
Cause
Remedy
Page
1-2
COIN ERROR 2
Service button failure or
some other problem near the
button
Contact your distributor.
1-11
COIN ERROR 1
(COIN UNIT 1)
COIN UNIT 1 failure
Replace the coin selector or
bill acceptor connected to
COIN UNIT 1.
COIN UNIT 1 wiring harness
failure
Contact your distributor.
1-21
COIN ERROR 1
(COIN UNIT 2)
COIN UNIT 2 failure
Replace the coin selector or
bill acceptor connected to
COIN UNIT 2.
COIN UNIT 2 wiring harness
failure
Contact your distributor.
1-31
COIN ERROR 1
(COIN UNIT 3)
COIN UNIT 3 failure
Replace the coin selector or
bill acceptor connected to
COIN UNIT 3.
COIN UNIT 3 wiring harness
failure
Contact your distributor.
2-3
BACKUP MEMORY
ERROR 1
Backup memory damage
Initialize the backup memory.
Page 34
MAIN PCB failure
Replace the MAIN PCB.
Page 55
2-4
BACKUP MEMORY
ERROR 2
Backup memory damage
Initialize the backup memory.
Page 34
MAIN PCB failure
Replace the MAIN PCB.
Page 55
2-5
BATTERY ERROR
The MAIN PCB backup
battery is dead.
Replace the battery.
Page 56
3-1
I/O ERROR 1
The connectors on the I/O
PCB are disconnected.
Connect them securely.
Page 57
I/O PCB failure
Replace the I/O PCB.
Page 57
3-3
I/O ERROR 2
The connectors on the I/O
PCB are disconnected.
Connect them securely.
Page 57
I/O PCB wiring harness
failure
Contact your distributor.
3-11
I/O ERROR 3
The connectors on the A.I.
PCB are disconnected.
Connect them securely.
Page 58
A.I. PCB failure
Replace the A.I. PCB.
Page 58
3-13
I/O ERROR 4
The connectors on the A.I.
PCB are disconnected.
Connect them securely.
Page 58
A.I. PCB wiring harness
failure
Contact your distributor.
To Purchase This Item, Visit BMI Gaming | www.bmigaming.com | (800) 746-2255 | +1.561.391.7200