background image

GB

Malfunctions and troubleshooting

7

Minor faults are often sufficient to cause a malfunction. In most cases, you will be able to correct 

these faults easily yourself. Please start by referring to the following table before contacting our 

technical support. This will help you save much effort and possibly expense.

Fault/malfunction

Cause

Remedy

Pump does not run. No mains voltage?

Check cables, plug, socket and fuse.

Motor overheats due to:

• liquid temperature too

high?

• blocking by foreign bod-

ies?

Eliminate the cause of the overheating 

(max. temperature of liquid 

Technical data – p. 8 ).

Residual current circuit break-

er (RCCB) triggered?

Activate RCCB.

Contact qualified electrician if RCCB 

triggers again.

Motor defective?

Contact service partner.

Pump runs but does 

not pump.

Suction openings blocked?

Rectify blockage.

Pump draws in air?

Keep the pump at an angle while sub-

merging.
Switch the pump on and off several 

times in order to expel air.

Pump blocked by foreign bod-

ies?

Clean the pump (

Cleaning the suc-

tion area – p. 6 ).

Delivery rate too low. Delivery height too great?

Comply with maximum delivery height 

(

Technical data – p. 8 ).

Pressure line diameter too 

small?

Use pressure line with larger diameter.

Pressure line blocked?

Rectify blockage.

Suction openings blocked?

Clean suction opening.

Pressure line kinked?

Straighten pressure line.

Pressure line leaks?

Seal pressure line, tighten threaded 

connections.

Pump runs very loud-

ly.

Pump draws in air?

Ensure there is sufficient liquid present.
Keep the pump at an angle while sub-

merging.

Содержание SP7580

Страница 1: ...SP7580...

Страница 2: ...nated swim ming pool water It must not be used for the drinking water supply or for the delivery of foodstuffs Explosive flammable aggressive or health hazardous substances and faecal matter must not...

Страница 3: ...en ponds and similar places the appliance must be equipped with a residual current circuit breaker RCCB with a design fault current of not more than 30 mA Do not kink crush drag or drive over the main...

Страница 4: ...sealing tape e g Teflon tape When using a hose screw a suitable hose adapter onto the pressure connection Push the hose firmly onto the hose adapter and secure with a hose clamp Installation The appli...

Страница 5: ...he end of the rope firmly after lowering The pump can also be operated while suspended on a rope Operation After the appliance has been connected to the mains power supply the pump can working Attenti...

Страница 6: ...spose of such old electrical and electronic equipment sepa rately Please check with your local authority about the possibilities for correct disposal Through separate disposal you send old equipment f...

Страница 7: ...ed electrician if RCCB triggers again Motor defective Contact service partner Pump runs but does not pump Suction openings blocked Rectify blockage Pump draws in air Keep the pump at an angle while su...

Страница 8: ...a fault yourself please contact our technical support directly Please note that improperly conducted repairs will void your warranty and may cause you additional expenses Technical data Model Item num...

Отзывы: