background image

超音波研磨装置 / 

UltraSonic Polisher

取   扱   説   明   書 / 

OPERATION MANUAL

OM-K0517 001

目  次

 

1

 . CAUTIONS FOR HANDLING AND OPERATION 

・・・

P

16

 

2

 . SPECIFICATIONS AND DIMENSIONS  

・・・・

P

18

 

3

 . COMPONANT NAMES 

・・・・・・・・・・・・・・・

P

18

 

4

 . PREPARATION BEFORE USE 

・・・・・・・・

P

22

 

5

 . ATTACHMENT OF THE TOOL 

・・・・・・・・

P

23

 

6

 . OPERATING PROCEDURES 

・・・・・・・・・

P

24

 

7

 . PROTECTION CIRCUIT 

・・・・・・・・・・・・・・

P

24

 

8

 . FINISHING OPERATION BY ULTRASONIC POLISHER 

・・・

P

25

 

9

 . CHANGING FUSES 

・・・・・・・・・・・・・・・・・・

P

26

10

. HOW TO SET THE CONTROL UNIT 

・・・・

P

27

11

. SYMBOLS 

・・・・・・・・・・・・・・・・・・・・・・・・・・・

P

27

12

. SIMPLE TEST METHOD USING THE TEST HORN 

・・

P

28

13

. TROUBLESHOOTING 

・・・・・・・・・・・・・・・・

P

29

 

1

 . 

安全上の注意・表示について

 

・・・・・・・・・・・

P  

2

 

2

 . 

仕 様

 

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

P  

3

 

3

 . 

各部の名称

 

・・・・・・・・・・・・・・・・・・・・・・・・・・・

P  

4

 

4

 . 

使用前の準備

 

・・・・・・・・・・・・・・・・・・・・・・・・・

P  

6

 

5

 . 

工具の交換方法

 

・・・・・・・・・・・・・・・・・・・・・・・

P  

7

 

6

 . 

操作方法

 

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

P  

8

 

7

 . 

保護回路について

 

・・・・・・・・・・・・・・・・・・・・・

P  

9

 8 . 

超音波仕上げ作業の要点

 

・・・・・・・・・・・・・・・

P  9

 9 . 

ヒューズの交換方法

 

・・・・・・・・・・・・・・・・・・・

P10

10. 

操作パネルの設定方法

 

・・・・・・・・・・・・・・・・・

P11 

11. 

シンボル

 

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

P11

12. 

テストホーンを使用した簡易的な振動確認方法

 

・・

P12

13. 

故障の原因と対策

 

・・・・・・・・・・・・・・・・・・・・・

P13

CONTENTS

Содержание Sheenus neo

Страница 1: ...G PROCEDURES P24 7 PROTECTION CIRCUIT P24 8 FINISHING OPERATION BYULTRASONIC POLISHER P25 9 CHANGING FUSES P26 10 HOW TO SET THE CONTROL UNIT P27 11 SYMBOLS P27 12 SIMPLE TEST METHOD USING THE TEST HORN P28 13 TROUBLESHOOTING P29 1 安全上の注意 表示について P 2 2 仕 様 P 3 3 各部の名称 P 4 4 使用前の準備 P 6 5 工具の交換方法 P 7 6 操作方法 P 8 7 保護回路について P 9 8 超音波仕上げ作業の要点 P 9 9 ヒューズの交換方法 P10 10 操作パネルの設定方法 P11 11 シンボル P11 12 テストホーンを使...

Страница 2: ...perly installed and grounded in accordance with all local codes and ordinances Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician Improper connection of the equipment grounding conductor can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is t...

Страница 3: ...Control Unit from moisture dust corrosive gasses near chloride vapors and out of direct sunlight All of which can cause pre mature failure Failure to protect the Control Unit can result in damage to internal components and result in injury to the operator Ultrasonic vibration may cause noise during use Earplugs or ear protection is recommended Never place the air vents upward or block the air vent...

Страница 4: ...ediately and check all components If the tool is broken do not continue to use the tool Replace with a new tool immediately The system functions normally in the environment where the temperature is at 10 40ºC 75 104ºF humidity at 30 75 RH and with no moisture or condensation near the Control Unit Usage outside of this recommended range may cause a malfunction Store the system in the place where th...

Страница 5: ...ch FC 24 1pc Allen Wrench 2 5mm 1pc Tool Case 1pc Handpiece Stand 1pc Standard Tools Tip holder Round for ȭ 3 0mm 1pc Tip holder Flat for t 1 0mm 1pc Ceramic fiber grindstone 800 Flat 6 50mm t 1 1pc Electroplated diamond file 200 Flat taper 4 50mm t 0 4 1pc 3 1 Standard Set Fig 1 2 3 Standard Accessories 3 COMPONANT NAMES Control Unit NE240 Handpiece US 25PB Foot Switch FC 24 Control Unit NE240 Ha...

Страница 6: ...y pressing the RESET Switch twice after correcting the problem DISPLAY Switch By pressing the DISPLAY Switch the LED display can be changed from Watt Power DISPLAY The selected Watt Power value is shown on the display WATT Electric power supplied to the oscillator is shown The heat generated in the Handpiece tip holder and tool is proportional to the power applied to the oscillator too much power ...

Страница 7: ...h the Protector Sleeve to the Handpiece Test Horn When you unpack the carton the Test Horn is attached to the front end of Handpiece The Test Horn is used to verify that the Handpiece is correcting generating the ultrasonic oscillation for normal operation When using the Handpiece remove the Test Horn from the Handpiece Tip Holder Holder to attach special tip tools One Piece Tool M 6 one piece too...

Страница 8: ...Control Unit Fig 6 3 Make sure that the Main Power Switch is OFF and connect the power cord to the Inlet with Power Supply Fuses of the Control Unit Fig 7 4 When using the Foot Switch connect the Plug of the Foot Switch to the Socket for Foot Switch Fig 8 Main Power Switch Receptacle for Connecting Handpiece Output Plug of the Handpiece Inlet with Power Supply Fuses Main Power Cord Socket for Foot...

Страница 9: ...d Allen Wrench 2 5mm If the clearance between the groove of the Tip Holders and the tool is too large do not use excess force to tighten Use a thin metal shim Reattach the Protector Sleeve Fig 10 5 3 M4 Screw Joint Adapter Attach the M4 Screw Joint Adaptor to the Handpiece and clamp tightly using the two provided wrenches Then attach the M4 One piece tool and clamp using the provided wrenches then...

Страница 10: ...ce and Control Unit causing tools to burn and cause injuries 3 Set the Power Control Knob to a minimum setting 4 Press the ON OFF Switch ON LED lamp will light up GREEN When operating by the Foot Switch the ON LED lamp will light up by pressing the Foot Switch 5 The display screen WATT POWER can be changed by pressing the DISPLAY Switch 6 Adjust output power to the optimum level for the work by tu...

Страница 11: ... greatly reduces the pressure required for fast material removal Do not press the tool too hard and make sure the tool fits the surface configuration properly If required you can grind the tool surface to the proper shape using diamond tools or sand paper Fig 12 Using flat surface Secure contact between the tool and the work surface Vibration direction Slide direction Using with angle 30 degree is...

Страница 12: ...e intended fuse only Recommended fuses AC120V T1 6AH 250V AC230V T1AH 250V 1 The Inlet with power supply fuses contains a fuse box inside Push the clips on both side of the cap in and pull the cap out 2 Use the intended fuse only Replace both of the fuses when replacing the fuses 3 Push the clips of the cap into the inlet firmly Fig 13 Inlet with Power Supply Fuses ...

Страница 13: ...hanging the non use auto shutdown time The Control Unit is equipped with a non use auto shutdown timer that will shutdown the Control Unit after extended periods of non use The default time is factory set to 3 minutes Turn OFF the Main Power Switch Turn ON the Main Power Switch with pressing the DISPLAY Switch The DISPLAY shows 03 Press the DISPLAY Switch and select the time 00 Not available 01 Tu...

Страница 14: ...n on the Test Horn Fig 16 5 As you gradually increase the Power Control Knob to MAX the water drop on the Test Horn become vapor as shown Fig 17 In case oscillation is not output or sufficient mist cannot be generated in the UNCLAMP mode check if the Test Horn is not tightly mounted on the Handpiece Retighten it and repeat above test If the condition does not improve return to NAKANISHI dealer ser...

Страница 15: ...n RESET LED lights up RED Too much pressure on the tool and the protection system activated Do not put too much pressure on the tool The Power Control Knob is set too high Adjust the Power Control Knob to a lower setting and restart T h e t h e r m a l p r o t e c t o r i s activated when in continuous operation Turn OFF the Main Power Switch and the system to cool down The tool has become loose R...

Страница 16: ...ng the Foot Switch ON LED not light up GREEN The plug of Foot Switch is not connected properly Connect the plug of Foot Switch properly The plug of Handpiece is not connected properly to the Receptacle for Connecting Handpiece Re connect the plug of Handpiece correctly The Foot Switch is defective Return to a NAKANISHI dealer for service The output cord is broken The ultrasonic oscillator or the C...

Страница 17: ...31 ...

Страница 18: ...2013 07 20 003 י ...

Отзывы: