79
English
③
Set by the Speed Point Signal
(Set parameter
. (Refer to P106 " 18 - 4
⑦
Selection of External Speed Control Mode " section.))
Select the 4 Speed Points set beforehand by combination of " Speed Point Select 0 (POINT 0) (Pin No. 17 :
SEL0) " and " Speed Point Select 1 (POINT 1) (Pin No. 5 : SEL1) ".
When selecting the Speed Point (
-
), turn the " Motor Select (Pin No. 15 : MT_SEL) " to " OFF
(Closed) ".
Table. 4 Combining Speed Point Select 0 (POINT 0) (Pin No. 17 : SEL0) with Speed Point Select 1 (POINT 1)
(Pin No. 5 : SEL1) for Motor No. 1
Speed Point
SEL1(Pin No. 5)
SEL0 (Pin No. 17)
OFF (Open)
OFF (Open)
OFF (Open)
ON (Closed)
ON (Closed)
OFF (Open)
ON (Closed)
ON (Closed)
When selecting the Speed Point (
-
) of Motor No. 2, turn the " Motor Select (Pin No. 15 : MT_
SEL) " to ' ON (Closed) '.
Table. 5 Combining Speed Point Select 0 (POINT 0) (Pin No. 17 : SEL0) with " Speed Point Select 1 (POINT 1)
(Pin No. 5 : SEL1) " for Motor No. 2
(5) Resetting System after Error Codes
Releasing Error Code by The " Error Release (Pin No. 4 : RESET) ". Switch the signal on " Error Release (Pin
No. 4 : RESET) " of Input / Output Connector A
③
' OFF (Open) '
→
' ON (Closed) '
→
' OFF (Open) '.
Error Signal will not be released until cause of the error has been removed.
Refer to P94 " 17 - 3 Resetting System after Error Codes " section.
Speed Point
SEL1 (Pin No. 5)
SEL0 (Pin No. 17)
OFF (Open)
OFF (Open)
OFF (Open)
ON (Closed)
ON (Closed)
OFF (Open)
ON (Closed)
ON (Closed)