Trouble

Inspection / Corrective Active

Broken connection hose and supply 
air / oil hose. 

Replace the connection hose and supply air / oil hose. 

No air ow.

Check the compressor power supply and the air compressor output.

Check if connection hose and supply air / oil hose is broken, bent or 
disconnected. 

Check the Filter Regulator and set to the correct air pressure.
Check all connection hose and supply air / oil hose connections.  

ON / OFF valve is OFF position. Turn the ON / OFF valve set to ON position.

Air leakage.

Check all threaded joints and re-tighten if necessary.

Low air pressure.

Check the Compressor, Air Circuit, and Filter Regulator.

Low Lubricating Oil or no Lubricating 
Oil.

 Check lubricator for proper Lubricating oil level. Set Lubricating oil drip 

rate from 1 to 3 drops /min. 

 Removing the air / oil hose from the Secondary Joint (

ȭ

6 One-Touch 

Joint), supply a small amount of oil directly into the air / oil hose if bowl is 
completely empty.

Insufcient number of oil drops.

Air Tool and Reducer internal components will be deprived of oil and the 
longevity will be dramatically shortened. 
Set the Oil Drip Rate from 1 to 3 drops / min.

Water in Lubricating Oil Reservoir.

Drain water from Lubricating Oil reservoir and replace with clean 
Lubricating Oil.

Water, dirt and debris are collected 
in the Filter Regulator.

Drain water, dirt and debris from the Filter Regulator bowl.

10

. TROUBLESHOOTING

If a problem or concern occur, please check the following items prior to consulting your dealer.

11

. DISPOSAL OF THE AIR LINE KIT

When disposal of an Air Line Kit is necessary, follow the instructions from your local government agency for proper 
disposal of industrial components.

Содержание AL-H1206

Страница 1: ...は圧縮エアーを使用してください エアー圧力は 1 次側 1 0MPa 以下 2 次側 0 85MPa 以下で 使用してください 圧縮エアーについて 化学薬品 有機溶剤を含有する合成油 塩分 腐食性ガス等を含む圧縮エアーは 使用しないでください ボウルの破損や作動不良の原因になります 配管用ホース 給気ホースの接続 ホースは 確実に接続してください 使用中にホースが外れるとホースがあばれ けがをするおそれがあ ります 配管用ホース耐圧 1 0MPa 以下 を守って使用してください 継手部について 継手部に衝撃を与えたり 負荷がかかる接続をしないでください 破損によりエアー漏れや 継手が折れ て配管用ホース 給気ホースがあばれるおそれがあります 落下について エアーラインキットを取り付ける場合は 平らな面に確実に取り付けてください エアーラインキットを 落下させた場合 故障やけがをするおそれが...

Страница 2: ...psi Pressure exceeding 1 0MPa 145psi may cause the connection hose and supply air oil hose to rupture Inlet and Outlet Connections Do not hit impact or cause shock to the Inlet or Outlet Connector Connections Never put undo stress or load on the Inlet or Outlet Connector Connections Any damage to these components can cause air leakage and the inability of the inlet or outlet quick disconnect to ad...

Страница 3: ...remove them as not to cause damage to them CAUTIONS for STORAGE INSTALLATION and OPERATION Do not use the Air Line Kit where corrosive gasses chemicals seawater water oils or steam exist Do not place in direct sunlight Do not use where the Air Line Kit is subject to vibration or repetitive shock Do not use where a heat source or radiated heat exist To conform to STORAGE INSTALLATION and OPERATION ...

Страница 4: ...ny Name Business Hours U S Toll Free No Telephone No Fax No Web Address Industrial Div 8 30am to 17 00pm CST closed Saturday Sunday and Public Holidays 800 585 4675 847 843 7664 847 843 7622 www nskamericacorp com Contact Us Contact Us For U S Market Company Name Business Hours Telephone No e mail Address 8 00am to 17 00pm closed Saturday Sunday and Public Holidays 81 0 289 64 3520 webmaster ie ns...

Страница 5: ...e Pressure Regulator Operating Range 0 05 0 85MPa 7 3 123 3psi Pressure Relief Automatic Relief Valve Applied lubricating oil ISO VG15 Liquid Paraf n or equivalent Oil Reservoir Capacity 85cm3 Dimensions W300mm x D120mm x H228mm Weight 2 2Kg Operation Environment Temperature 0 40 C Humidity MAX 75 No condensation Atmospheric pressure 800 1 060hPa Transportation and Storage Environment Temperature ...

Страница 6: ...cator are damaged all components are replacable by the end user Refer to Table 2 and Table 3 Table 2 Name Model Manufacturer Filter Regulator W1000 8 W CKD Lubricator L3000 8 W C Table 3 Filter Regulator Replacing Option Name Model Manufacturer Filter Regulator Consumable Parts Kit This set includes the Diaphragm Assy Valve Assy Bottom spring Louver Element Baf e and Bowl O Ring W1000 KIT CKD Lubr...

Страница 7: ...Regulator Knob IN to the Lock position Adjusting Air Pressure Turn the Regulator Knob while watching Pressure Gauge increase or decrease H direction Air pressure is increased L direction Air pressure is decreased 2 Filter Section The water dirt and debris are separated from the compressed air The separated debris is collected in the Bowl Draining Opening and closing the Drain Valve O direction Dra...

Страница 8: ...e Kit install to the horizontal If Rear Mounting install the Air Line Kit to the horizontally on a vertical wall 9 1 Installation of the Air Line Kit 1 Horizontal Installation When the Air Line Kit is mounted from the bottom in a horizontal position Af x the Rubber Pads Standard Accessories 4pcs to the bottom of the Air Line Kit 2 Rear Mounting or Bottom Mounting Attach the Air Line Kit by the Mou...

Страница 9: ...r Compressor IMPULSE Air Tool Fig 8 1 Connect the Connection Hose Standard Accessory to the Primary Joint of the Air Line Kit 2 Connect the Filter Joint of the air motor to the Secondary Joint ȭ6 One Touch Joint on the Air Line Kit 3 Place Exhaust Air Silencer Oil Hose into an empty container Exhaust outlet air and oil from the Siliencer 9 2 Connection of the Air Line Kit ...

Страница 10: ...t Lubricating oil drip rate from 1 to 3 drops min Removing the air oil hose from the Secondary Joint ȭ6 One Touch Joint supply a small amount of oil directly into the air oil hose if bowl is completely empty Insuf cient number of oil drops Air Tool and Reducer internal components will be deprived of oil and the longevity will be dramatically shortened Set the Oil Drip Rate from 1 to 3 drops min Wa...

Страница 11: ...2015 06 20 002 י ...

Отзывы: