Description of commands
NDRA91-92
Manual
LDM301-302 Manual
Page 76
ASTECH GmbH
Query:
SD
Set:
SDx y
Parameter value
range x:
0, 1, 2
Parameter value
range y:
0, 1, 2, 3 (Table 26 : Serial output format SDy,
parameter y)
Standard:
0 0
The parameter y allows additional to the measurement value the output of
signal strength and / or the output of temperature.
Table 26 : Serial output format SDy, parameter y
y
SD0 y
SD1 y
SD2 y
Decimal
Hexadecimal
Binary
0
Measurement value
Measurement value
Measurement value
1
Measurement value,
Signal strength
Measurement value,
Signal strength
Measurement value,
Signal strength
2
Measurement value,
Temperature
Measurement value,
Temperature
Measurement value,
Temperature
3
Measurement value,
Signal strength,
Temperature
Measurement value,
Signal strength,
Temperature
Measurement value,
Signal strength,
Temperature
Explanation binary output format
Distance: 3 Byte,
MSB = Bit 7
MSB of Byte 2 always 1
MSB of Byte 1 and 0 always 0
Measurement data: Byte 0 and 1 = Bit 6 … Bit 0
Coding: Two’s compliment
Scaling factor binary values to decimal values: 1/1000
Содержание NDRA91
Страница 1: ...Manual NDRA91 92 Firmware Version from 1 5 Version 2 0 ...
Страница 41: ...NDRA91 92 Manual Interface description NADO Page 41 Figure 17 Example of switching output wiring ...
Страница 43: ...NDRA91 92 Manual Interface description NADO Page 43 Figure 20 Wiring analog output QA of NDRA91 ...
Страница 90: ...Notice NDRA91 92 Manual Page 90 NADO ...
Страница 91: ...NDRA91 92 Manual Notice NADO Page 91 ...