SF – Scaling factor
SFx enables the scaling of the output measurement value by the
parameterization of the factor x.
Query:
SF
Set:
SFx
Parameter value
range x:
-10 … -0.001 and 0.001 … 10; resolution: 0.000001
Standard:
1.000000
OF – Offset
With OF, the user specific offset x is parameterized. This value is added to the
measurement value.
Query:
OF
Set:
OFx
Parameter value
range x:
float32; resolution: 0.001
Standard:
0.000
No plausibility test of the set offset is carried out within the
NDRA91
; the user
is responsible to set the correct parameterization!
SO – Set offset
With the parameter SO, a single distance measurement is carried out and set
as OF (Offset). SO can only be executed, in this way, it is not a parameter in
the strict sense.
SO is used for the zero-adjustment of applications, systems, processes etc.
MW – Measurement window
The range of the measurement window is parameterized with MW, which
outputs only measurement values within the window, starting with x and
terminating with y.