Cleaning the Thermostatic Cartridge 

1. Before carrying out any maintenance, turn off both water supplies to the shower valve. If unsure contact a
     qualified plumber.
2. Remove the cap, screw, temperature handle, then remove the limiter ring. 

Note: take note of the position of

    the limiter ring, they must be re-fitted in the same position.

3. Push the buttons of the thermostatic cartridge outward and pull the flow handle forward at the same time.

    

Please take care not to damage the button during removing the flow handle. S

ee Fig 3. 

4. Remove the retaining nut using a suitable spanner, remove and clean the thermostatic cartridge. Rinse

    

thoroughly under cold water to remove any build up of limescale or debris. 

Note: Take note of the position of 

    the thermostatic cartridge, as it must be refitted in the same position.

5. If necessary replace the thermostatic cartridge.

6. Re-fit the cartridge into the body and tighten the retaining nut using a suitable spanner.
7. Re-fit the on/off and flow handle, limiter ring and temperature handle. Tighten the screw and re-fit cap to 

    handle.
    

Note: The square holes of the flow handle needs to be in alignment with the buttons of the thermostatic

    cartridge and push back in place.

Buttons

Fig 3

Cap

Screw

Temperature handle

Temperature limiter ring

On/off and flow control handle

Retaining nut

Thermostatic cartridge

Valve body

Содержание A05041

Страница 1: ...Concentric Thermostatic Shower Valve Instructions Product code A05041 Please keep these instructions for future reference ...

Страница 2: ...t by a qualified and competent person and in accordance with the instructions supplied Installations must comply with all Local and National Water Authority Regulations and Building Plumbing Regulations Ensure that you have read and understood all sections of this manual before installation Water Supply Temperature Pressures Hot Water Temperature Range Recommended 60 65 C Cold Water Temperature Ra...

Страница 3: ...e construction Drill holes to suit required fixings Use wall plugs supplied as required 4 Secure wall bracket to the wall using the wall screws supplied 5 Fit the flange fixing nuts and copper olives over the inlet pipes 6 Insert the filters into the elbows 7 Make sure that the elbows align with the inlet pipes push valve body to the wall bracket and pipes with the outlet to the bottom and secure ...

Страница 4: ...e diameter Inlet pipes not supplied 150 1 mm 20mm Valve body Temperature control handle On off and flow control handle Grub screw Copper olives Fixing nuts Wall screw Hexagonal key Flange Wall bracket Wall plug Filter Elbows Lever Wall plate ...

Страница 5: ...ll screws supplied 5 Fit the flange fixing nuts and copper olives over the exposed inlet pipes 6 Insert the filters into the elbows 7 Make sure that the elbows alignment with the pipes push valve body to the wall bracket and pipes with the outlet to the bottom and secure with the two grub screws supplied using an 2 5mm hexagonal key at the same time See Fig 2 Carefully tighten securely the nuts of...

Страница 6: ...checked if required using a thermometer If this temperature is incorrect you can reset it by the following 1 Turn the temperature handle to 38 C stop position 2 Remove cap then the screw then pull the temperature handle off the spindle 3 Without removing the limited ring turn the spindle of thermostatic valve carefully using pliers until the temperature is at the required level 4 Test again using ...

Страница 7: ...r remove and clean the thermostatic cartridge Rinse thoroughly under cold water to remove any build up of limescale or debris Note Take note of the position of the thermostatic cartridge as it must be refitted in the same position 5 If necessary replace the thermostatic cartridge 6 Re fit the cartridge into the body and tighten the retaining nut using a suitable spanner 7 Re fit the on off and flo...

Страница 8: ...ed to the highest of standards and should require little or no maintenance In the unlikely event of any spare part requirements please contact our telephone helpline number Telephone Helpline Should you require any technical help in association with your Nabis product please call 0344 292 7060 with your query Warranty 5 Years For detailed warranty information please visit our website www nabis co ...

Отзывы: