Te
mperature Setting
(To be changed only when essential)
This mixer has been factory set under balanced water pressures with a hot water supply at 65˚C.
When your operating conditions vary significantly from the above, the temperature of the mixed water may vary
from the setting. In this case, you can set the temperature of the mixer to suit your requirements.
The valve is set to a maximum 45˚C. This can be checked if required using a thermometer. If this temperature is
incorrect, you can reset it by the following:
1. Turn the temperature handle to 38˚C stop position.
2. Remove cap, then the screw, then pull the temperature handle off the spindle.
3. Without removing the limited ring, turn the spindle of thermostatic valve carefully using pliers until the
temperature is at the required level.
4. Test again using a thermometer.
5. When the required temperature is reached, re-fit the components, so that the stop will be at your new set
temperature.
Cap
Screw
Temperature handle
Temperature limiter ring
Thermostatic valve