Nabis A05041 Скачать руководство пользователя страница 5

1. 15mm diameter pipework should be installed and flushed before commencing installation. 

    (1) Ensure distance of inlet pipe centres is 150 mm and that they protrude 20mm from the inner wall cavity

         and that the wall bracket is central. Adjust if required.

    (2) 

Recess depth required 54-75 mm (Please refer to dimensioned diagram).

2. Place valve body against wall with elbows over pipe ends. Mark position of valve body on wall. Remove valve 

    body, place wall bracket in centre of marked position and mark position for fixing holes.

 

See Fig 1.

    

Note: the centre distance of two elbow is adjustable, the adjustment dimension is 145-155mm. You can

    adjust the centre distance of the elbow ( screw the two elbows clockwise / anticlockwise) as required.

3. See Safety Note. 

Important - Use appropriate fixings suitable for wall type/construction.

 Drill holes to 

     suit required fixings (Use wall plugs supplied as required).
4. Secure wall bracket to the wall using the wall screws supplied.  
5. Fit the flange, fixing nuts and copper olives over the exposed inlet pipes. 
6. Insert the filters into the elbows. 
7. Make sure that the elbows alignment with the pipes, push valve body to the wall bracket and pipes with the 

    outlet to the bottom and secure with the two grub screws supplied using an 2.5mm hexagonal key at the same

    time. See Fig 2. 
    Carefully tighten securely the nuts of the elbows using a spanner (not supplied). See Fig 2.

8. Connect pipework to outlet of the valve body, 

9. Turn on water supply and check for leaks.

10. If watertight, install a cover plate (not suppled) or finish wall surface/tiles leaving sufficient access for future
      servicing/maintenance.

    

 Note: The wall plate can be used as a template for the access hole size by placing on the valve and 

     drawing around the plate and measuring in by 15mm to allow sufficient surface area around the hole
     for wall plate fixing.

11. When wall surface is completed fit the wall plate to the shower valve and up to the wall surface. (Use a

       suitable sealant as necessary).

12. Screw lever to on/off flow control handle.

150±1 mm

Fig 1

The position of

valve body.

Fig 2

Содержание A05041

Страница 1: ...Concentric Thermostatic Shower Valve Instructions Product code A05041 Please keep these instructions for future reference ...

Страница 2: ...t by a qualified and competent person and in accordance with the instructions supplied Installations must comply with all Local and National Water Authority Regulations and Building Plumbing Regulations Ensure that you have read and understood all sections of this manual before installation Water Supply Temperature Pressures Hot Water Temperature Range Recommended 60 65 C Cold Water Temperature Ra...

Страница 3: ...e construction Drill holes to suit required fixings Use wall plugs supplied as required 4 Secure wall bracket to the wall using the wall screws supplied 5 Fit the flange fixing nuts and copper olives over the inlet pipes 6 Insert the filters into the elbows 7 Make sure that the elbows align with the inlet pipes push valve body to the wall bracket and pipes with the outlet to the bottom and secure ...

Страница 4: ...e diameter Inlet pipes not supplied 150 1 mm 20mm Valve body Temperature control handle On off and flow control handle Grub screw Copper olives Fixing nuts Wall screw Hexagonal key Flange Wall bracket Wall plug Filter Elbows Lever Wall plate ...

Страница 5: ...ll screws supplied 5 Fit the flange fixing nuts and copper olives over the exposed inlet pipes 6 Insert the filters into the elbows 7 Make sure that the elbows alignment with the pipes push valve body to the wall bracket and pipes with the outlet to the bottom and secure with the two grub screws supplied using an 2 5mm hexagonal key at the same time See Fig 2 Carefully tighten securely the nuts of...

Страница 6: ...checked if required using a thermometer If this temperature is incorrect you can reset it by the following 1 Turn the temperature handle to 38 C stop position 2 Remove cap then the screw then pull the temperature handle off the spindle 3 Without removing the limited ring turn the spindle of thermostatic valve carefully using pliers until the temperature is at the required level 4 Test again using ...

Страница 7: ...r remove and clean the thermostatic cartridge Rinse thoroughly under cold water to remove any build up of limescale or debris Note Take note of the position of the thermostatic cartridge as it must be refitted in the same position 5 If necessary replace the thermostatic cartridge 6 Re fit the cartridge into the body and tighten the retaining nut using a suitable spanner 7 Re fit the on off and flo...

Страница 8: ...ed to the highest of standards and should require little or no maintenance In the unlikely event of any spare part requirements please contact our telephone helpline number Telephone Helpline Should you require any technical help in association with your Nabis product please call 0344 292 7060 with your query Warranty 5 Years For detailed warranty information please visit our website www nabis co ...

Отзывы: