1. 15mm diameter pipework should be installed and flushed before commencing installation.
(1) Ensure distance of inlet pipe centres is 150 mm and that they protrude 20mm from the inner wall cavity
and that the wall bracket is central. Adjust if required.
(2)
Recess depth required 54-75 mm (Please refer to dimensioned diagram).
2. Place valve body against wall with elbows over pipe ends. Mark position of valve body on wall. Remove valve
body, place wall bracket in centre of marked position and mark position for fixing holes.
See Fig 1.
Note: the centre distance of two elbow is adjustable, the adjustment dimension is 145-155mm. You can
adjust the centre distance of the elbow ( screw the two elbows clockwise / anticlockwise) as required.
3. See Safety Note.
Important - Use appropriate fixings suitable for wall type/construction.
Drill holes to
suit required fixings (Use wall plugs supplied as required).
4. Secure wall bracket to the wall using the wall screws supplied.
5. Fit the flange, fixing nuts and copper olives over the exposed inlet pipes.
6. Insert the filters into the elbows.
7. Make sure that the elbows alignment with the pipes, push valve body to the wall bracket and pipes with the
outlet to the bottom and secure with the two grub screws supplied using an 2.5mm hexagonal key at the same
time. See Fig 2.
Carefully tighten securely the nuts of the elbows using a spanner (not supplied). See Fig 2.
8. Connect pipework to outlet of the valve body,
9. Turn on water supply and check for leaks.
10. If watertight, install a cover plate (not suppled) or finish wall surface/tiles leaving sufficient access for future
servicing/maintenance.
Note: The wall plate can be used as a template for the access hole size by placing on the valve and
drawing around the plate and measuring in by 15mm to allow sufficient surface area around the hole
for wall plate fixing.
11. When wall surface is completed fit the wall plate to the shower valve and up to the wall surface. (Use a
suitable sealant as necessary).
12. Screw lever to on/off flow control handle.
150±1 mm
Fig 1
The position of
valve body.
Fig 2