Getting Started 

2-6

U30 Microprocessor Control 

www.NabcoEntrances.com

Part #15-9000-30 

Rev. 3-12-13

Table 2-2 

U30 Microprocessor Control Specifications

Specification

Description

Recommended Temperature Range

-4° to 140°F (-20° to +60° C)

Maximum recommended door weight

600 pounds total

(300 pounds each for a bi-part or 600 pounds for a single)

Hold Open time delay

0 to 67 seconds

Door Movement range

4 to 137 inches (100 to 3500 millimeters)

Door Movement range for Limited Door 

Opening Feature

4 to 137 inches (100 to 3500 millimeters)

Back Check range

2 to 5 inches (50.8 to 127 millimeters)

Function

LED

LED Display

Power

Red

(LED will blink when an error occurs)

61 (Activation)

Green

6B (Holding Beam)

Green

H (Reduced Opening)

Green

62 (Activation)

Green

BA (Panic Breakout and OFF)

Green

ERROR

Red

Table 2-3 

U30 Microprocessor Control Software Specifications

Program

Description

History Data

Maintains data under the History Data program

Maintenance Count

Counts number of times Handy Terminal has been connected for service and tracking.

Operation Count

Counts number of full door operations

(Operation counts are registered in increments of 100 per power-on period)

Recycle Count

Counts number of times the slide door has recycled.

Содержание U30

Страница 1: ...Door if a Safety System is not working Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician Failure to follow these practices may resul...

Страница 2: ...Wiring 4 10 Section 4b The Handy Terminal 4 10 Section 4c Connecting the Handy Terminal 4 11 Section 4d Initialization of the Handy Terminal Display 4 12 Section 4e Disconnecting the Handy Terminal 4...

Страница 3: ...f severe injury or death It should not be considered for property damage unless personal injury risk is present Indicates a hazardous situation which has some probability of severe injury It should no...

Страница 4: ...in whether power supply is disconnected always verify using a voltmeter Notice Wiring must meet all local state federal or other governing agency codes All electrical troublshooting or service must be...

Страница 5: ...able standards In the United States ANSI Standard 156 10 is used to cover Slide door systems Other local standards or codes may apply Use them in addition to the ANSI standards Instruct the building o...

Страница 6: ...be made by authorized NABCO facilities Adjustments to the door can only be made with the NABCO Handy Terminal GYRO TECH NAB CO fire ly Mode SW Usage Gnd Gnd Gnd Open Open Open Gnd Open M0 M1 MODE TWO...

Страница 7: ...o 3500 millimeters Back Check range 2 to 5 inches 50 8 to 127 millimeters Function LED LED Display Power Red LED will blink when an error occurs 61 Activation Green 6B Holding Beam Green H Reduced Ope...

Страница 8: ...ensor that is active in one way mode 4 6B Holding Beam White Holding Beam Input Opens or re opens a door when the holding beam signal is activated 5 H Reduced Opening Switch Green Reduced Opening Inpu...

Страница 9: ...ith a Stripe Color 2 e g Black Red Black wire with a Red Stripe Rocker Switch Settings When wires M0 and M1 are switched to Red 7 the state is indicated by ON Mode Wire M0 Wire M1 Wire H Description T...

Страница 10: ...ies the signal for the activation circuit that will open the door from a closed position in TWO WAY mode only Black Red 62 wire usually connects to the exterior motion sensor BA Green Panic Breakout a...

Страница 11: ...LD OPEN Toprotect against risk of fire or electric shock use only the certified NABCO power supply WARNING MOTOR 12P ERROR POWER BA 62 H 6B 61 INDICATORS POWER 2P Do not disassemble the control box Th...

Страница 12: ...s and remove the protective Cap Set aside a The Handy Terminal Harness should already be connected to the bottom of the U 30 Microprocessor Controller via a telephone jack 3 Connect the plug end of th...

Страница 13: ...ill cause damage to both the Cable and Terminal Harness Section 4f Determine Correct Handing 1 With power off manually slide the door open half way 2 Turn power ON The Slide door should slowly close p...

Страница 14: ...heck point 9 STD FUNCTION Y N message will be displayed after the Test is completed a This concludes the initial setup to factory settings 10 If the U30 Microprocessor Control X X Does not need to be...

Страница 15: ...e fastest 0 is the slowest For details on incremental Close speed adjustments please refer to P N 15 9000 30 U30 Microprocessor Control Manual The U30 Microprocessor Control Rev D requires the Closing...

Страница 16: ...er to reduce door speed to the check or latch speed Zero provides gradual braking and 7 provides abrupt braking Reaction Power Message will read REACTION POWER 4 Eight options are available Controls h...

Страница 17: ...lowly the door will slowly reach the full open position and then close Two Slide door will slowly reach the full open position then close Three Slide door stays in manual open position until activated...

Страница 18: ...ly when selecting 0 or 2 on the Auxiliary output 1 Determines when the internal form C relay connected to OUT A Normally Open or OUT B Normally Closed and OUT C Common terminals is picked This interna...

Страница 19: ...4 seconds Two 6 seconds Three 8 seconds Three Message will read AUX OUTPUT 3 A Relay Signal indicating a fully closed position will be provided Used by the Gyro Tech Access Control Panel or other simi...

Страница 20: ...l door operations Updated every 100 door cycles Counter displays up to 6 553 500 cycles Recycle Cnt Indicates number of times the Slide door reversed direction after sensing An object was struck The a...

Страница 21: ...ire Black Red 62 wire is normally connected to the exterior activation sensor Y Normally Closed Circuit N Normally Open Circuit Signal Input for White 6B on Terminal 4 Message will read FUNCTION 3 N D...

Страница 22: ...Sidelite Sensor Setting chart option 1 or 0 that defines the Slide door behavior shown below Function Setting Door Position Door reaction when Sidelite Sensor is Activated Option set to 0 Fully Close...

Страница 23: ...0 7 Setting 0 has no effect Allows Open speed to be set in between the Standard Open Speed settings found in Standard Function Adjustments Example Given After setting up the Slide door it was found t...

Страница 24: ...quires adjusting Output Timer 2 to select the time delay between the first and second door operations Three Signal at Full Closed Transistor will turn ON to indicate the Slide door reached a fully clo...

Страница 25: ...ameters 2 Do not choose Y for Swing Door when setting door parameters Stroke Set Correctly CLOSE SPEED TIME DELAY OPEN SPEED LATCH C SPEED BACK C SPEED REACTION POWER CHECK POWER START POWER HOLD CLOS...

Страница 26: ...recycles on its own Cause Obstructions during the closing cycle will cause the Slide door to recycle open Operation should continue as soon as recycling is done Obstructions during the opening cycle...

Страница 27: ...delites closed voltage should equal 0 VDC If voltage is 12 VDC the panic breakout circuit is open Check the Blue wire and determine where the circuit is open LED indicator BA may help Abnormal door op...

Отзывы: