2 of 3
GT1175 Telescopic, U19 Electric Lock Kit Instruction Sheet
www.NabcoEntrances.com
P/N C-00336
Rev 3-15-18
3. Mark and drill out (1) Retangle Hole and (4) Rivnut Holes onto the front face of the Box Beam according to the Template
located in CHAPTER 5.
4. Insert (1) 1/4-20 Rivnut into each Rivnut hole.
5. Insert the Electric Lock into the Cutout.
6. Ensure the Flat side of Latch faces the Strike on the Electric Lock.
7. Loosely secure the Electric Strike to the Box Beam with (4) 1/4-20 x 1” Screws and 1/4” Lock Washers.
8. Fully close the Slide door.
a. A slight gap must exist between the Latch and the Strike.
b. Ensure the Belt Clip does not hit the Speed Reducer Roller.
9. Fully Open the Slide Door. Ensure the Belt Clip does not hit the Drive Belt Roller.
10. Make adjustments if deemed necessary.
DN 1968
Slight Gap
Strike
Flat side of Latch
Speed Reducer Roller
Drive Belt Roller
Door Fully Closed
Door Fully Open
Figure 2 Ensure Terminal Strip is Facing Strike Side of Slide Door
CHAPTER 3: GENERAL WIRING
Attention: Electric Lock only works in One Way mode or Night Mode.
DN 1913
FAIL
SECURE
VIO
GRY
WHT
BLK
1
6
110V
Wire Nut
103125
BROWN 60"
VIOLET 60"
No.
HANDY TERMINAL (6P)
SENSOR (12P)
1.Please adjust this operator as per instruction manual.
2.Turn the power off, before opening the box.
3.Don't open this box except for replacing fuse.
Otherwise, the warranty will be terminated.
4.Repair of this unit except by Lanson Industries, Inc.
may cause software and hardware malfunction.
USE [SLIDER/SWINGER]
For continued protection
against fire, replace only
with same type and rating
of fuse.
WARNING
FUSE INSIDE
RATING:125V,4A
SIZE:5.2 x 20mm
COLOR
BROWN
RED
BLACK
WHITE
GREEN
ORANGE
ORANGE
ORANGE
YELLOW
BLUE
VIOLET
GRAY
7
61
6B
9DC12V
SYMBOL
H
M0
M1
62
BA
OUT +
OUT -
SQ
1
2
3
4
NO.
5
6
7
8
9
10
11
12
POWER SOURCE (4P)
OPERATOR (6P)
EMPTY
115VAC HOT
EMPTY
115VAC COMMON
WHITE
BLACK
1
2
3
4
COLOR
NO.
MOTOR V PHASE
ENCODER 12VDC
ENCODER A PHASE
MOTOR U PHASE
ENCODER GND
ENCODER B PHASE
ORANGE
RED
BROWN
YELLOW
COLOR
BLUE
BLACK
1
2
3
4
5
6
NO.
OUT+
(VIOLET)
OUT-
(GRAY)
7 (RED)
9DC12V
(BROWN)
GREY 10"
VIOLET 10"
BROWN 60"
VIOLET 60"
GREY 10"
VIOLET 10"
BROWN 60"
VIOLET 60"
GREY 10"
VIOLET 10"
FAIL SECURE RELAY WIRING
FAIL SAFE RELAY WIRING
U-SERIES CONTROL
(U19 OR EARLIER)
RELAY
LOCK
TO 120VAC
All manuals and user guides at all-guides.com