CHAPTER 2: SCOPE

SECTION 2.1: To the Installer

The purpose of this manual is to familiarize the installer with the proper installation and operation of this system.  It is essential 

that this equipment be properly installed and operational before the door is used by the public.  It is the installer’s responsibility 

to inspect the operation of the entrance system to be sure it complies with any applicable standards.  In the United States, ANSI 

Standard 156.10 (Used to cover Full Energy doors) and ANSI Standard 156.19 (Used to cover Low Energy doors) apply.  Other local 

standards or codes may apply.  Use them in addition to the ANSI standards.   
The owner should determine the door is operating properly and should immediately call for service if there is any malfunction. All 

installation changes and adjustments must be made by qualified, NABCO trained technicians.
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 

between 8 am – 4:30 pm Central time for additional assistance.

SECTION 2.2: Objective

The Opus Control is designed to be installed within the Header of:

X

X

New Swing and Folding Doors.

X

X

Existing swing and folding doors using Analog, Magnum, or U01-U19 controls (works with encoders or 

microswitches). 

X

X

Existing sliding doors using U01-U19 controls. Retrofit kits can be purchased by contacting Customer Service at  

1-888-679-3319.

This manual offers step by step instructions. Do Not take shortcuts.

CHAPTER 3: FEATURES

Specification

Description

Power Close

Built-in

Back Check Angle Adjustment

5 to 35 degrees from Full Open position

Used with Encoder Motor only.

Latch Check Angle Adjustment

10 to 40 degrees from Full Closed position

Used with Encoder Motor only.

Built In Sequencer

Can activate:

Electric Locks

Electric Strikes

Electric Latch Retracted Panic Devices

CHAPTER 4: SPECIFICATIONS

SECTION 4.1 General Specifications

Specification

Description

Temperature Range

-13 degrees to 140 degrees Fahrenheit

Motor Type

DC Brush Motor with Encoder, 115V

Number of Signal Inputs

1 x Activation

2 x Door Mode

2 x Safety

1 x Sequential

1 x Breakout (stop)

2 x Programmable

Number of Outputs

1 x Electric Lock Form C Relay

2 x Programmable Transistor Outputs

SECTION 4.2 Electrical Specifications

Note: All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits that might be commonly 

used. On site wiring may be different from that shown. 

Note: NABCO factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to 

manufacture all Automatic Door systems.

Содержание Opus Control

Страница 1: ...HAPTER 1 SAFETY 2 CHAPTER 2 SCOPE 3 SECTION 2 1 To the Installer 3 SECTION 2 2 Objective 3 CHAPTER 3 FEATURES 3 CHAPTER 4 SPECIFICATIONS 3 SECTION 4 1 General Specifications 3 SECTION 4 2 Electrical S...

Страница 2: ...esult in seriouc personal or fatal injury When uncertain whether power supply is disconnected always verify using a voltmeter Do not place finger or uninsulated tools inside the electrical controller...

Страница 3: ...nd Folding Doors X X Existing swing and folding doors using Analog Magnum or U01 U19 controls works with encoders or microswitches X X Existing sliding doors using U01 U19 controls Retrofit kits can b...

Страница 4: ...er 24 VAC P N A 01185 The Opus Control must Not be used to output power to X X Magnetic Locks X X Electric Strikes To determine if an auxiliary power supply must be used add the total current draw of...

Страница 5: ...of Header End Cap Attention Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting cash registers or any device that might cause electrical interference on t...

Страница 6: ...Communication 7 CN1 Power Connector 4 Rotary Dial 8 Fuse CHAPTER 7 THE ROTARY DIAL X X Push down on the Rotary Dial Long push 2 seconds to gain access to LCD Catagory Screens Short push under 2 second...

Страница 7: ...lose Recycle Cnt Latest Recycle Posi on DN 1334 LEVEL 4 Push and Hold Rotary Dial 2 Sec Rotate Dial Rotate Dial Rotate Dial Short Push Figure 3 LCD Screen Transition SECTION 8 1 Level One Specificatio...

Страница 8: ...oke Learning Go to Se ng menu Reset to Default Set Yes No Passcode Stroke Learning Yes No Ac vate Passcode Rotate Dial Rotate Dial Rotate Dial Figure 6 Level Two Screen Attention To prevent tampering...

Страница 9: ...oints should happen Stroke Learning is also used to determine if an existing Operator Type is correct and or to determine if Handing is correct 1 Briefly press down on the Rotary Dial to select X X Ye...

Страница 10: ...ly Open X X Slide Door 1 to 13 3 4 of Fully Open Close Speed 0 7 3 The higher the number the faster the Door closes Latch Check Speed 0 7 3 Sets door speed during latch check Latch Check Range 0 7 3 X...

Страница 11: ...essure Manual Open Function No Action No Action Does nothing Push and Go P G Enables push and go Stop and Close S C Door pauses at open angle then closes Open Assist X X Assisted Power from motor when...

Страница 12: ...X X Sensor Monitoring N C X X BEA Bodyguard Output Full Open X X Output doesn t change state X X Output changes when fully closed X X Output changes when door is closing X X Output changes when door...

Страница 13: ...e to reduced open Emergency Close Forces the door to slowly close and lock if equipped Hold Open Mode Causes the door to hold open forever Input H Open Timer N A Same as Open Timer 0 thru 10 12 15 20...

Страница 14: ...or slide doors it displays the position in inches from closed Test Open Tests Open Close door cycle while ignoring Safety Signals CHAPTER 9 COMMON PROGRAM ADJUSTMENTS SECTION 9 1 Stroke Learning UNIT...

Страница 15: ...PECS Passcode Go to Se ng menu Stroke Learning Yes No Push and Hold Rotary Dial 2 Sec LEVEL 1 LEVEL 2 1 Rotate Dial to select Go to Se ng menu 2 Push Rotary Dial Se ng Category LEVEL 3 History Se ng P...

Страница 16: ...Sequential activation Signal to open Signal to close 10 H Programmable input 11 M0 Mode 0 When grounded puts door into One Way Mode Hold Open when grounded with M1 12 M1 Mode 1 When grounded puts door...

Страница 17: ...17 of 32 www NabcoEntrances com Opus Control Wiring and Programming Installation Manual Rev 10 20 17 P N C 00139 SECTION 10 2 Switches and Sensors with Monitoring DN 1895...

Страница 18: ...ces Non Powered Activation Devices WARNING Total Power Consumption Of All Sensors And Powered Activation Devices Must Not Exceed 750 mA 7 6 5 4 3 2 1 3 2 4 All Device Outputs Must Be N O Dry Contact 7...

Страница 19: ...3 2 1 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Exterior Push Plate Interior Push Plate COM N O COM N O All Devices Must Be N O Dry Contact Powered Activation Devices sensor card reader radio receiver etc Powe...

Страница 20: ...or Slide Door Sidelite Sensor 7 Out1 Programmable Output 14 13 12 11 10 9 8 7 6 5 4 3 2 1 7 6 5 4 3 2 1 2 4 COM N O PWR PWR 1 Door Mounted Approach Side Sensor Door Mounted Swing Side Sensor CO O PWR...

Страница 21: ...com Opus Control Wiring and Programming Installation Manual Rev 10 20 17 P N C 00139 SECTION 11 4 Safety with Monitoring Door Mounted Swing Side Sensor Door Mounted Approach Side Sensor Overhead Swing...

Страница 22: ...4 13 12 11 10 9 8 7 6 5 4 3 2 1 Fail Secure Electric Strike Fail Secure Lock Shown Fail Safe and Mag Locks will use N C instead of N O Power Supply For Electric Strike N O COM N C Varistor MOV TVS DO...

Страница 23: ...G TOTAL POWER CONSUMPTI ON OR ALL SENSORS MUST NOT EXCEED 750 mA ON OFF Hold Open Switch P N A 00805 COM N O PWR PWR COM N O PWR PWR COM N O PWR PWR COM N O PWR PWR va on Sensor Overhead Swing Side Se...

Страница 24: ...24 of 32 Opus Control Wiring and Programming Installation Manual www NabcoEntrances com P N C 00139 Rev 10 20 17 SECTION 11 7 Single Full Automatic with Monitoring DN 1658...

Страница 25: ...N O PWR PWR 1 RED BLUE BLACK 14 13 12 11 10 9 8 8 WHITE 14 13 12 11 10 9 8 7 6 5 4 3 2 1 6 4 5 COM N O PWR PWR Door Mounted Approach Side Sensor Door Mounted Swing Side Sensor COM N O PWR PWR COM N O...

Страница 26: ...26 of 32 Opus Control Wiring and Programming Installation Manual www NabcoEntrances com P N C 00139 Rev 10 20 17 SECTION 11 9 Simultaneous Pair Full Automatic with Monitoring DN 1660...

Страница 27: ...430 Clear A 70430 Dark Bronze RED BLACK 14 13 12 11 10 9 8 8 WHITE Off Hold Open On Off 14 13 12 11 10 9 8 8 14 BA break out input must be set to N C on the Opus Control is by default Panic Latch must...

Страница 28: ...r connecting to a second Opus for Sim Pair Astragal Sequencing 14 13 12 11 10 9 8 10 14 Example of a switch being used to turn on off Power Close and Hold Closed Programmable input H terminal 10 would...

Страница 29: ...irm that IN or EXT highlights when an activation signal isapplied If not check the wiring or the activation device X X At the main screen determine if BA is highlighted If a 4 wire on off hold openswi...

Страница 30: ...he Opus will stop door movement Possible causes are X X Abnormal voltage at Motor Circuit X X Abnormal current draw from motor X X Check all connections between the Control and Motor X X Check Motor F...

Страница 31: ...00888 CONTROLLER OPUS W CHASSIS BRAKE 9 M 01072 HARNESS POWER MAGNUM BOARD 10 V 00713 Used on A 01249 FUSE 2 AMP 5X20MM 250V FAST ACTING 11 A 01249 Used on GT710 8710 only HARNESS MOTOR OPUS 710 12 A...

Страница 32: ...T 10 7 M 01680 HARNESS OPUS CONTROL SIM PAIR 8 A 01098 CONTROLLER W BRAKE BOTTOM LOAD OPUS 9 M 01735 PLATE BOTTOM LOAD OPUS 10 A 01143 CONTROLLER W O BRAKE BOTTOM LOAD OPUS 11 A 01003 Not used on GT71...

Отзывы: