Topic 

Page Number 

 
Introduction 

 ................................................................................................................................................. 4 

 

To The Installer        ................................................................................................................. 4 

 

Overview .................................................................................................................................. 4 

 

Modes of Operation ................................................................................................................. 4 

 
Specifications   ................................................................................................................................................. 5 
 
Programming instructions ................................................................................................................................ 6 
 
Mode 1 - Electric Strike Sequence Diagram - Magnum 4 Control .................................................................. 7 
Mode 1 - Electric Strike Sequence Diagram - Analog Control ........................................................................ 8 
 
Mode 1 - Bi-directional Door Sequencer Diagram - Magnum 4 Control.......................................................... 9 
Mode 1 - Bi-directional Door Sequencer Diagram - Analog Control ............................................................. 10 
 
Mode 2 - Apartment or Access Control Diagram - Magnum 4 Control .......................................................... 11 
Mode 2 - Apartment or Access Control Diagram - Analog Control ............................................................... 12 
 
Mode 3 - Ratchet or Latching Operation Diagram - Analog Control ............................................................. 13 
 
Mode 4 - Smoke Evacuation Diagram - Magnum 4 Control .......................................................................... 14 
Mode 4 - Smoke Evacuation Diagram - Analog Control ................................................................................ 15 
 
Mode 5 - Acugard Lock-out Relay Diagram - Magnum 4 Control ................................................................. 16 
Mode 5 - Acugard Lock-out Relay Diagram - Analog Control ....................................................................... 17 
 
Mode 6 - Washroom Control Relay Diagram - Magnum 4 Control ............................................................... 18 
Mode 6 - Washroom Control Relay Diagram - Analog Control ..................................................................... 19 
 
NABCO ENTRANCES Return Policy ............................................................................................................ 14 

Содержание GYRO TECH Nabco Multi-Module

Страница 1: ...nction Module for the Control of Swing Slide and Fold Doors WARNING Do not install or service this product unless you have read and understood the Safety Practices Warnings Installation and Operating...

Страница 2: ...tion Manuals Service Bulletins AutoCAD Drawings Specifications Sales Literature Unit Pricing Online Ordering News Releases Promotional Materials and much more Just log in with your distributor account...

Страница 3: ...or Sequencer Diagram Analog Control 10 Mode 2 Apartment or Access Control Diagram Magnum 4 Control 11 Mode 2 Apartment or Access Control Diagram Analog Control 12 Mode 3 Ratchet or Latching Operation...

Страница 4: ...one panels Isolates interphone panel voltages from automatic door operator Also can be used to interface with access control systems that have timed lock functions Refer to diagram labeled Mode 2 Apar...

Страница 5: ...Outputs 2 form C SPDT Relay contact rating 4 amps 30VDC Time delays Relay 1 on time 0 5 30 sec Delay on operate Relay 2 1 30 sec Relay 2 on time 0 5 30 sec To protect the Multi Module from voltage sp...

Страница 6: ...be flashed by the relays and LEDs Example the board is in mode 3 and the button is pressed for more than 2 seconds The LEDs will flash 3 times To advance to the next mode the switch is again pressed...

Страница 7: ...ELAY1 RELAY2 RADIO RECEIVER 4 TERM Power COM N O STRIKE ELECTRIC TVS Connect Transient supplied directly to strike Voltage Suppressor Not polarity sensitive iti 200S If magnetic lock or fail safe stri...

Страница 8: ...nection 2 Power supply inputs not polarity sensitive If magnetic lock or fail safe strike used connect lock wires to COM and N C terminals of Multi Module iti 200S TVS ELECTRIC STRIKE N O COM Power 4...

Страница 9: ...circle indicates a wire connection 3 Power supply inputs not polarity sensitive Normally Open Dry Contacts OPTIONAL VESTIBULE PUSH SWITCH BROWN BLACK RED WHITE VIOLET ORANGE Normally Open Dry Contacts...

Страница 10: ...n Dry Contacts OPTIONAL VESTIBULE PUSH SWITCH Normally Open Dry Contacts NOTE 1 When the module is triggered by push switch DRY1 Relay 1 will activate first then after an adjustable delay Relay 2 will...

Страница 11: ...DRY COM COM WET WET1 N O COM N C N C COM N O 12V 24V LED LED RL2 RL1 RELAY 1 ON TIME DOO DELAY ON OPERATE RELAY 2 RELAY 2 ON TIME SW 1 MODE SWITCH DN 0302 BROWN BLACK RED WHITE VIOLET ORANGE 1 2 3 4...

Страница 12: ...Y ON OPERATE RELAY 2 RELAY 1 ON TIME RL1 RL2 LED LED 24V 12V N O COM N C N C COM N O WET1 WET COM COM DRY DRY1 DRY2 WET2 WET3 RELAY1 RELAY2 iti 200S TVS STRIKE ELECTRIC Powered Signal Unlocks door onl...

Страница 13: ...RY2 DRY1 DRY COM COM WET WET1 N O COM N C N C COM N O 12V 24V LED LED RL2 RL1 RELAY 1 ON TIME DOO DELAY ON OPERATE RELAY 2 RELAY 2 ON TIME SW 1 MODE SWITCH DN 0302 Interior Switch Normally Open Dry Co...

Страница 14: ...t Transient supplied directly to strike Voltage Suppressor iti 200S If magnetic lock or fail safe strike used connect lock wires to COM and N C terminals of Multi Module Note 1 A black circle indicate...

Страница 15: ...COM COM WET WET1 N O COM N C N C COM N O 12V 24V LED LED RL2 RL1 RELAY 1 ON TIME DOO DELAY ON OPERATE RELAY 2 RELAY 2 ON TIME SW 1 MODE SWITCH DN 0302 NOTES 1 In smoke evacuation or maintained operato...

Страница 16: ...l WET Shown with maintained Fire Alarm Panel 12 24V AC DC FIRE To match strike voltage DN 0302 Activation Connector on Analog Control BLACK RED Normally Open Dry Contacts PUSH SWITCH Connect Transient...

Страница 17: ...Magnetic Door Position Switch P N 14 11313 Contacts should close when door is closed Connect to COM and N O terminals on switch Activation Push Plate Normally Open Dry Contacts N O COM 8 7 6 5 4 3 2 1...

Страница 18: ...ty sensitive Activation Push Plate Normally Open Dry Contacts Transformer P N 14 2101 24 VAC 120 VAC 24 VAC These Potentiometers have no effect Acugard 3 LE on Non swing side of door P N 21 10158 35 1...

Страница 19: ...O DELAY ON OPERATE RELAY 2 RELAY 2 ON TIME SW 1 MODE SWITCH DN 0302 Terminal Strip on Magnum Control BROWN BLACK RED WHITE VIOLET ORANGE 1 2 3 4 5 6 Interior Push Plate Normally Open Dry Contacts Exte...

Страница 20: ...e when door is closed Connect to COM and N O terminals on switch Magnetic Door Position Switch P N 14 11313 Exterior Push Plate Normally Open Dry Contacts Interior Push Plate Normally Open Dry Contact...

Страница 21: ...fied within 2 weeks of failure of all warranty claims All parts for warranty claims must be returned to NABCO within the following two 2 weeks for US locations and six 6 weeks for all other locations...