MODE 5 - ACUGARD LOCK OUT RELAY DIAGRAM - MAGNUM 4 CONTROL
6
5
4
3
2
1
ORANGE
VIOLET
WHITE
RED
BLACK
BROWN
Terminal Strip on Magnum Control
DN 0302
SW 1
MODE
SWITCH
RELAY 2
ON TIME
DOO
(DELAY
ON
OPERATE)
RELAY 2
RELAY 1
ON TIME
RL1
RL2
LED
LED
24V
12V
N.O. COM N.C.
N.C.
COM
N.O.
WET1
WET
COM COM
DRY
DRY1
DRY2
WET2
WET3
RELAY1
RELAY2
iti-200S
Magnetic Door Position Switch
P/N 14-11313
Contacts should close when door is
closed - Connect to COM and N.O.
terminals on switch.
Activation Push Plate
Normally Open - Dry Contacts
N.O
COM
8
7
6
5
4
3
2
1
Acugard 3 LE on Non-swing side of door
P/N 21-10158-35
NOTES:
1.
Sensor only active after push
plate is actuated. It will stay
active until the door shuts and
door position switch closes.
Multi-Module will reset after 2
minutes if the door does not
open for any reason.
2.
A black circle indicates a
wire connection.
3.
Power supply inputs not
polarity sensitive.
These Potentiometers have no effect