background image

(Revised 2014-01-23) 

13 

FCC STATEMENT 

 
This product complies with Part 15 of the FCC-A Rules. 
Operation is subject to the following conditions: 
(1)

 

This device may not cause harmful Interference 

(2)

 

This  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 
operation. 

 
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. Operation of this device in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his own expense. 
 

 
 
INDUSTRY CANADA 
 

This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment 
Regulations. Operation is subject to the following two conditions; (1) this device digital apparatus meets all 
requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the 
following two conditions; (1) this device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation. 

 

Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant 
des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne 
pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y 
compris l'interférence qui peut causer l'opération peu désirée. 

 

 

Содержание 1002MC-LX-YY

Страница 1: ...Revised 2014 01 23 1 1000 Series Gigabit Media Converter Industrial Gigabit Ethernet Switch User Manual Installation Guide...

Страница 2: ...00BaseLX singlemode fiber switch 1003GX2 B Custom mix and match 1003GX2 switch 1005TX 5 port gigabit Ethernet switch Where YY is 10 for 10km max fiber segment length 40 for 40km max fiber segment leng...

Страница 3: ...n contained in this document is subject to change without notice N Tron Corporation makes no warranty of any kind with regard to this material including but not limited to the implied warranties of me...

Страница 4: ...circuit est sous tension sauf si la zone est connue pour tre non dangereux WARNING Use 110 C or higher rated copper wire 0 22Nm 2 lb in tightening torque for field installed conductors ALERTE Utilisez...

Страница 5: ...les during periods of lightning activity ALERTE Ne pas travailler sur le mat riel ou les c bles pendant les p riodes d activit de la foudre WARNING Observe proper DC Voltage polarity when installing p...

Страница 6: ...utilize the RJ45 shielded connectors The 1002MC MCE is a two port unmanaged media converter that converts 10 100 1000Base T copper to 1000BaseSX LX full duplex fiber The 1003GX2 GXE2 is a three port...

Страница 7: ...G Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation Lire l avertissement suivant avant de commencer l installation WARNING ALERTE Never install or...

Страница 8: ...it snaps into place To remove the unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up...

Страница 9: ...ty LED SPD1000 1000 Speed LED LEDs The table below describes the operating modes LED Color Description ON Power is Applied OFF Power is OFF LNK ACT ON Link established no Activity on cable BLINKING Li...

Страница 10: ...lug is 0 5 Nm 0 368 Pound Foot All LEDs will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation...

Страница 11: ...ve output terminal and the chassis grounding point of the switch As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a...

Страница 12: ...he same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network Alerte Cr ation d un port de connexion du port sur le m me commutateur c boucle est une o...

Страница 13: ...cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian...

Страница 14: ...ipple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10...

Страница 15: ...pprovals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divis...

Страница 16: ...le Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 00...

Страница 17: ...pprovals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divis...

Страница 18: ...e Inrush Current 13 Amp 0 61 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 1...

Страница 19: ...d Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4 cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 Hazardous Locations EMI EN61000 6 4 EN55011 Clas...

Страница 20: ...RANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON...