102MC/MCE - KEY SPECIFICATIONS 
 
Physical 
Height: 

 

 

 

2.90” (max.)  

Width:  

 

 

 

1.50” (max.) 

Depth Including Din-Rail Clip: 

4.82” (max.) 

Weight:    

 

 

 

0.60 lbs. 

 
Electrical 
Input Voltage:  

 

 

10-30 VDC (Regulated) 

Input Current:  

 

40mA max. @ 24VDC (Steady State) 

Inrush Current: 

 

 

8.5Amp/0.7 ms max. @ 24VDC 

Input Ripple:   

 

 

Less than 100 mV 

Input Wire Size: 

 

 

16-28 AWG 

 
Environmental 
Operating Temperature:        

-40°C to 80°C 

Storage Temperature:       

 

-40°C to 85°C 

Operating Humidity:   

 

10% to 90% (Non Condensing) 

Operating Altitude:   

 

0 to 10,000 ft. 

 
Network Media 
10BaseT: 

 

 

> Cat-3 Cable 

100BaseT: 

 

 

> Cat-5 Cable 

100BaseFX:   

 

Multimode: 50-62.5/125µm Fiber 

 

 

 

 

Singlemode: 7-9/125µm Fiber

 

Fiber Transceiver Characteristics 

Fiber Length: 

2km* 

15km** 

40km** 

  80km** 

TX Power Min/Max  -19dBm/-14dBm  -15dBm/-7dBm  5dBm/0dBm 

-5dBm/0dBm 

RX Sensitivity Max:  -32dBm 

-34dBm 

-34dBm 

-34dBm 

Wavelength: 

1310nm 

1310nm 

1310nm 

1550nm 

*=Multimode  ** =Singlemode 
 
Connectors
 
10/100BaseTX: 

RJ45 UTP Port 

100BaseFX:   

SC or ST Duplex Port 

 
Recommended Minimum Wiring Clearance: 
 
Front:  5” (12.7 cm)  
Top:  1" (2.54 cm) 

 

Содержание 100 Series

Страница 1: ...5 17 2007 1 100 Series Media Converter Industrial Ethernet Switches User Manual Installation Guide...

Страница 2: ...5 17 2007 2 Industrial Media Converter Installation Guide 102MC XX 102MCE XX YY 104TX 105TX 108TX Where XX ST or SC and YY 15 40 or 80...

Страница 3: ...n contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchanta...

Страница 4: ...it with the end plates removed as this could create a shock or fire hazard WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnec...

Страница 5: ...replace the device unless power has been switched off or the area is known to be non hazardous 5 Use 60 75 C rated Copper wire 022Nm 2 inch lbs Tightening torque for field installed connectors 6 WARN...

Страница 6: ...seFX full duplex fiber The 104TX 105TX and 108TX are affordable and share a small footprint Each switch is capable of auto negotiating 10 100 Mb and half full duplex communications The 102MC utilizes...

Страница 7: ...e packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installat...

Страница 8: ...remove the unit from the 35mm industrial DIN rail place a flat head screwdriver into the release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the...

Страница 9: ...s two LED s located at the left side of the connector The top LED indicates Activity ACT and the lower LED indicates Link LNK status LED s The table below describes the operating modes LED Color Descr...

Страница 10: ...0 22 Nm 0 162 Pound Foot All LED s will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1...

Страница 11: ...ay be verified by using a voltmeter to determine that there is no voltage difference between the power supply s negative output terminal and the chassis grounding point of the switch As an alternative...

Страница 12: ...RJ45 connector Connect the other end to the far end station Verify that the LNK LED s are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standa...

Страница 13: ...harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Inter...

Страница 14: ...I Div 2 Groups A B C and D UL Temperature Ratings 102MC MCE T5 104TX 105TX and 108TX T4A EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN6100...

Страница 15: ...rature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125 m Fiber Singlemo...

Страница 16: ...4VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Alti...

Страница 17: ...VDC Steady State Inrush Current 8 1 Amp 0 7ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operat...

Страница 18: ...ES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OP...

Отзывы: