Multipoint Control Box 8

InstallatIon Manual

7

Crimping instructions

  never insert uncrimped plugs into 

the sockets.

  

Doing so may cause damage to 
the socket contacts. Crimped plugs 
should insert easily into sockets 
until the locking tab clicks into place. 
Plugs that have been incorrectly 

crimped may be difficult to insert, 

and may cause damage to the 
socket contacts if forced into place.

 

Step 1

• 

Cut the cable to the desired length. 
take care to ensure the ends are cut 
square. 

Step 2

• 

Insert the cable between the stripper 
blades of the crimping tool so that it 
touches the metal stop. 

• 

squeeze the handles and pull the tool 
to remove the cables outer sheath 
and expose the insulated inner 
conductors. 

• 

Ensure the insulation on the inner 
conductors is not damaged. 

  Cable connections are polarity 

conscious. 

 

It is essential that every cable 
termination for each installation is 
performed with the coloured inner 
conductors in the same order and 
position in the plug. any two cable 
ends should appear identical if held 
side by side (provided they are of 
the same cable type - i.e. shielded or 
unshielded). 

Step 3

• 

Insert a plug into the plug holder 
of the crimping tool. It will click into 
place. 

• 

Insert the prepared cable end into 
the plug, taking care to ensure the 
coloured inner conductors are in the 
same order and position each time. 

• 

Squeeze the handles firmly to set the 

contacts and secure the cable. 

Содержание Multipoint Control Box 8

Страница 1: ...l Box 8 Installation Manual Spill Zones Plug Play 8 7 6 5 Zone Motors 4 3 2 1 Zone Motors www metalflex com au MPCBT8 Touchpads 24VAC Supply A N Clock Option Fujitsu Bridge MOTOR OUTPUTS MOTOR OUTPUTS ON 1 2 3 4 5 6 7 8 ...

Страница 2: ...magnetic radiation sources Avoid dust contamination Avoid highly corrosive environments Cabling Requirements All data cables wall switch should be 6 core 5 1 shielded flat cable with 6p6c plugs Data cables should be kept as far from power cables as practical minimum 300mm Motor cables can be 6 core flat cable with 6p6c plugs or 4 core flat cable with 6p4c plugs Multipoint Control Box 8 Zone Module...

Страница 3: ...ir handling unit or in the mechanical services switchboard The wall switch should be mounted in a central location within the air conditioned space They are designed to be flush mounted to a cavity wall but may be surface mounted through the use of a mounting block not less than 15mm deep The motorised dampers can be mounted at the takeoff point of the rigid duct or mounted in line in the flexible...

Страница 4: ...e wall switch See image next page Once the number of zones for the wall switch has been selected place the zone labels in the appropriate position on the front of the switch prior to sticking the overlay in place Wall Switch Zone Number Assignment MPWS234 MPWS234 Jumper Position Zones Controlled JP1 Top 1 2 3 and 4 JP2 Middle 1 2 and 3 JP3 Bottom 1 and 2 Wall Switch Zone Number Assignment MPWS56 M...

Страница 5: ...Multipoint control box 8 Installation Manual 5 MPWS234 Multipoint Multipoint Multipoint MPWS56 Multipoint Multipoint MPWS78 Multipoint Multipoint ...

Страница 6: ...per motor being used In the event of a power loss and restore to the controller ie blackout the controller will resume operation with all zones in the on off state last set by the user Basic Connection Diagram Spill Zones Plug Play 8 7 6 5 Zone Motors 4 3 2 1 Zone Motors www metalflex com au MPCBT8 Touchpads 24VAC Supply A N Clock Option Fujitsu Bridge MOTOR OUTPUTS MOTOR OUTPUTS ON 1 2 3 4 5 6 7 ...

Страница 7: ... handles and pull the tool to remove the cables outer sheath and expose the insulated inner conductors Ensure the insulation on the inner conductors is not damaged Cable connections are polarity conscious It is essential that every cable termination for each installation is performed with the coloured inner conductors in the same order and position in the plug Any two cable ends should appear iden...

Страница 8: ...Reece Group 118 Burwood Highway Burwood Victoria 3125 Australia Tel 1800 032 566 Reece Group Pty Ltd 118 Burwood Highway Burwood Victoria 3125 Australia Tel 1800 032 566 Made in PRC ...

Отзывы: