background image

Multipoint Control Box 8

InstallatIon Manual

6

Wall Switch operating instructions:

to operate a zone, simply press the 

 button to turn the respective zone on or off.

the green lED beside the 

 button is illuminated to indicate the zone is on.

Full airflow should be available from ten seconds to two minutes after switching the zone 

on, depending on the stroke time of damper motor being used. 

In the event of a power loss and restore to the controller (ie. blackout), the controller will 
resume operation with all zones in the on / off state last set by the user.

Basic Connection Diagram:

Spill Zones

&

Plug

Play

8

7

6

5

Zone Motors

4

3

2

1

Zone Motors

www.metalflex.com.au

MPCBT8

Touchpads

24VAC Supply

A N

Clock Option

Fujitsu Bridge

MOTOR OUTPUTS

MOTOR OUTPUTS

ON

1 2 3 4 5 6 7 8

EZ

Multipoint

EZ

Multipoint

Included

Transformer

GPO

Zone 4 

Damper

Zone 3 

Damper

Zone 2 

Damper

Zone 1

Damper

Zone 8 

Damper

Zone 7

Damper

Zone 6 

Damper

Zone 5

Damper

Содержание Multipoint Control Box 8

Страница 1: ...l Box 8 Installation Manual Spill Zones Plug Play 8 7 6 5 Zone Motors 4 3 2 1 Zone Motors www metalflex com au MPCBT8 Touchpads 24VAC Supply A N Clock Option Fujitsu Bridge MOTOR OUTPUTS MOTOR OUTPUTS ON 1 2 3 4 5 6 7 8 ...

Страница 2: ...magnetic radiation sources Avoid dust contamination Avoid highly corrosive environments Cabling Requirements All data cables wall switch should be 6 core 5 1 shielded flat cable with 6p6c plugs Data cables should be kept as far from power cables as practical minimum 300mm Motor cables can be 6 core flat cable with 6p6c plugs or 4 core flat cable with 6p4c plugs Multipoint Control Box 8 Zone Module...

Страница 3: ...ir handling unit or in the mechanical services switchboard The wall switch should be mounted in a central location within the air conditioned space They are designed to be flush mounted to a cavity wall but may be surface mounted through the use of a mounting block not less than 15mm deep The motorised dampers can be mounted at the takeoff point of the rigid duct or mounted in line in the flexible...

Страница 4: ...e wall switch See image next page Once the number of zones for the wall switch has been selected place the zone labels in the appropriate position on the front of the switch prior to sticking the overlay in place Wall Switch Zone Number Assignment MPWS234 MPWS234 Jumper Position Zones Controlled JP1 Top 1 2 3 and 4 JP2 Middle 1 2 and 3 JP3 Bottom 1 and 2 Wall Switch Zone Number Assignment MPWS56 M...

Страница 5: ...Multipoint control box 8 Installation Manual 5 MPWS234 Multipoint Multipoint Multipoint MPWS56 Multipoint Multipoint MPWS78 Multipoint Multipoint ...

Страница 6: ...per motor being used In the event of a power loss and restore to the controller ie blackout the controller will resume operation with all zones in the on off state last set by the user Basic Connection Diagram Spill Zones Plug Play 8 7 6 5 Zone Motors 4 3 2 1 Zone Motors www metalflex com au MPCBT8 Touchpads 24VAC Supply A N Clock Option Fujitsu Bridge MOTOR OUTPUTS MOTOR OUTPUTS ON 1 2 3 4 5 6 7 ...

Страница 7: ... handles and pull the tool to remove the cables outer sheath and expose the insulated inner conductors Ensure the insulation on the inner conductors is not damaged Cable connections are polarity conscious It is essential that every cable termination for each installation is performed with the coloured inner conductors in the same order and position in the plug Any two cable ends should appear iden...

Страница 8: ...Reece Group 118 Burwood Highway Burwood Victoria 3125 Australia Tel 1800 032 566 Reece Group Pty Ltd 118 Burwood Highway Burwood Victoria 3125 Australia Tel 1800 032 566 Made in PRC ...

Отзывы: