background image

MYSON CONTROLS

MYSON LTD., EASTERN AVENUE,

TEAM VALLEY, GATESHEAD,

TYNE & WEAR, 

NE11 0PG

SALES OFFICE No. 0845 402 3434

IN ACCORDANCE WITH OUR POLICY OF CONTINUAL PRODUCT IMPROVEMENT WE 
RESERVE THE RIGHT TO AMEND THE SPECIFICATION OF THESE PRODUCTS WITHOUT 
PRIOR NOTIFICATION. 

SETUP FOR SMART-START.

To toggle the Smart-Start function between enabled and disabled, 
hold        and       down for 10 seconds. The         button can now be 
used to toggle Smart-Start between active and deactivated.

CONFIGURING FOR WEEKLY OR

DAILY TIMING.

To toggle between weekly or daily time settings, hold        and        
down for 10 seconds. The        button can now be used to toggle 
between enabled and disabled.

CONFIGURING FOR GAS OR OIL

To toggle between Oil or Gas hold         and         down for 10 
seconds. The  L   button can be used to toggle between 
Oil and Gas.

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

TECHNICAL DATA: 

Precision of measured temperature: 0.1

o

C

Set temperature range: 6

o

C to 32

o

C

Electrical Protection: Class II

Ingress Protection: IP30

Power Supply: 230 Vac 

+

/- 10% , 50 Hz

Statutory Compliance:  EMC 89\336\EEC,

 

 

 

LVD 2006\95\EEC

Pollution Situation: Normal

Software Class: A

Output Relay Rating: 8(3)A 250Vac

ACTIVATING THE MPRT MS.

Remove the plastic strip that is preventing the battery connection 
in the battery compartment.

The LCD should display as shown below.
Re-assemble the unit to the base by first locating the right hand 
side and then closing the left . 

MON

 TUE WED

THU FRI SAT SUN

High Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

MON TUE WED THU FRI SAT SUN

0

2

4

6

8 10 12 14 16 18 20 22 24

High Setting

Current
Time

MON TUE WED
THU FRI SAT SUN

TO ACCEPT & CONTINUE PRESS OK 
TO CHANGE VALUE PRESS   OR  

TO ACCEPT & CONTINUE PRESS OK 
TO CHANGE VALUE PRESS   OR  

FOR LOW PRESS “L”, FOR MEDIUM PRESS “M”, FOR HIGH PRESS “H”
TO ACCEPT & CONTINUE PRESS OK

  

Low Setting

Current

Temp

0

2

4

6

8 10 12 14 16 18 20 22 24

12 14 16 18 20 22 24

 SAT SUN

SMART START

12 14 16 18 20 22 24

 SAT SUN

SMART START

0

2

4

6

8 10

0

2

4

6

8 10

0

2

4

6

8 10

0

2

4

6

8 10

STEP 4.

It is essential that the terminal cover must be replaced and 
secured with the screws removed in STEP 1.

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

OK

H

M

L

HEAT

TIMES

OFF

MAN

1 Hr

SC2450 - R1

1 2 3

To heating

equipment

c

WIRING THE MPRT

To heating

equipment

MPRT Back Cover 

1

2
3

The MPRT is wired directly to the

heating equipment.

To heating

equipment

1

5

1

2

3

5

4

6

1
2
3

0

C

Power input

230 V

AC 50Hz 

Live

Neutral

4
5
6

Отзывы: