background image

05

04

5.0  Controls

KICKSPACE

®

 500E ECO & 600E ECO

KICKSPACE

®

 500E ECO & 600E ECO

5.0  Controls 

(continued...)

This unit is controlled by the switches on the front of the unit  
(see Fig. 3) and a wireless programmable thermostat.
The wireless programmable thermostat includes many features 
and also ensures the electric KICKSPACE

®

 products comply with 

the 

Commision Regulation (EU) 2015/1188

. These features 

can be identified on the display of the wireless programmable 
thermostat (see Fig. 4).

Locating the Wireless Programmable Thermostat

The wireless programmable thermostat includes a flip out stand 
and can be freestanding in a suitable location. Alternatively it 
can be wall mounted, fitting instructions can be seen in Fig. 5. 
Wherever the wireless programmable thermostat is mounted/
used it should be out of direct sunlight, away from draughty 
areas and clear of any potential heat sources. For optimum use 
the thermostat should be fitted at a height of 1.5m from the 
floor (see Fig. 6).

First use of the Wireless Programmable Thermostat

The KICKSPACE

®

 unit will only run in ‘Fan Only’ mode without 

pairing the remote control unit. Once paired, the KICKSPACE

®

 

will be able to operate in ‘Heating’ mode, also.
To pair the remote to the KICKSPACE

®

; ensure that the 

KICKSPACE

®

 unit is energised and the ‘Heating System’ switch 

on the unit is switched to ‘Heating’ mode (red dot).

Remove the plastic insulator in the battery compartment to 
activate the remote control. The remote will show the software 
version number briefly and then show the ‘Comfort Mode’ 
factory default setting of 19°C.

Note:

 Leave the remote unit in ‘Comfort Mode’ to access the 

menu for pairing.
Pairing is done by accessing “rF ini” in the ‘Installer Parameters’ 
menu. To access the Parameters menu, press and hold the ‘OK’ 
button for approx. 12 seconds.

After 3 seconds of pressing the ‘OK’ button, the screen will 
display the time, continue to press ‘OK’ for a further 7-8 seconds 
until “bl no” is displayed. Release the ‘OK’ button. Click the (+) 
arrow to bring up “rF ini”.
Click ‘OK’ on “rF ini” and it will begin to flash while connecting 
to the KICKSPACE

®

. Once connected it will automatically 

redirect you to the main display.

Note:

 If no connection is made after approx.. 1min, “rF ini” will 

stop flashing.
Once the KICKSPACE

®

 and remote control unit have paired you 

will notice the following changes:
1.  The parameters menu has changed to a reduced KICKSPACE

®

 

only menu as detailed in section 5.0.

2.  The remote default set temperatures change, so for example in 

‘Comfort Mode’ the initial default of 19 °C changes to 21 °C.

Please Note:

 The room temperature sensor is in the remote 

control and handling of the remote control during the pairing 
process can increase the sensor temperature, preventing 
the KICKSPACE

®

 from operating if the standard ‘Comfort’ 

temperature is still set at 21°C.
If the KICKSPACE

®

 is either switched off or into ‘Fan Only’ 

mode, the pairing between with KICKSPACE

®

 is temporarily lost. 

However, provided that the remote control remains active the 
pairing will automatically be re-established if the KICKSPACE

®

 is 

subsequently switched back into ‘Heating’ mode. Reconnection 
may take up to 5 minutes.

If No Connection Is Made?

If the remote control unit and the KICKSPACE

®

 do not pair there 

a few things you may want to try:
1.  Repeat the pairing procedure.
2.  Double check that the KICKSPACE

®

 has the Heating System 

Switch set to ‘Heating’ (red dot).

3.  Isolate the power supply to the KICKSPACE

®

 for at least 30 

secs to clear any ‘bugs’, and remove the batteries from the 
remote control unit for the same period, then repeat the 
pairing procedure.

Setting the date and time

Use 

  and  

  keys to choose from the following parameters.  

A function is selected when the icon is surrounded by  .

1. Select 

 and press OK. 

2. Press 

(OK)

 the hours will begin to blink.

3. Use    or     to change the hour and press 

(OK)

 to confirm,  

 

the minutes will then begin to blink. 

4. Use    or    to change the minutes and press 

(OK)

 to  

 

confirm, the day number will then display.

5. Use    or     to change the day number, with Monday being  

 

1 and press 

(OK)

 to confirm, the date and month will then  

 

display and the day will begin to blink.

6. Use    or     to change the day and press 

(OK)

 to confirm,  

 

the month will then begin to blink.

7. Use    or     to change the month and press 

(OK)

 to confirm,  

 

the year will then display and begin to blink.

8.  Use  

  or  

  to change the year and press 

(OK)

 to confirm,  

 

and then scrolll 

  or  

 to go back to the main menu.

 

5.0

Operating Modes

Use 

  and  

  keys to choose from the following parameters. A function is selected when the icon is surrounded by   .

Function

Description

Adjustment

Comfort Mode

Provides room temperature control for when 
the room is occupied (see Fig. 3).
Heating mode – Electric
To enter this mode:
•  Set the fan only/off/heating switch to 

heating (red dot)

•  Set the output switch to position I
•  Select the fan speed switch to position I
The unit will now run on low speed.
To operate the 500E ECO at 2kW or the 600E 
ECO at 3kW:
•  Set the output switch to position II
The unit will now run on high output.

The display will show the ambient temperature. 
Press OK, set temperature will begin to blink. 
Use 

  or  

 to adjust the required room temperature. 

Press OK to confirm. 
The ambient room temperature will then display.
Default s21°C 
Max temp s30°C 
Min temp s5.5°C 
Note: The thermostat has a LED indicator that will change colour 
depending on the following: 

21.0°C = Green 

21.5°C - 24.0°C = Orange 

24.5°C = Red

Note: To see the set temperature simply press 

.

Auto

Automatic Setting

The unit will run according to one of the 9 
preset timed programmes, or one of the 4 user 
defined programmes.

See page 6 for ‘Programme Mode’ setup.
Note: When in AUTO mode it is possible to override by selecting 
a new temperature. To do this while in AUTO mode, press (OK), 
the temperature will begin to blink, change the temperature 
using 

  or  

  and press (OK) to confirm. The

symbol will 

display showing the override and this will last for 2 hours. To 
remove the override you can press 

.

Note: To see the set temperature simply press 

 again.

Night Set-back Setting

Provides room temperature controls for when 
the room is not occupied.

The display will show the ambient temperature. 
Press (OK), set temperature will begin to blink. 
Use 

  or  

 to adjust the required room temperature. 

Press (OK) to confirm. 
The ambient room temperature will then display.
Default s19°C 
Max temp s19°C - night set back temperature can not be 
higher than comfort mode set point. 
Min temp s5.5°C
Note: To see the set temperature simply press 

.

Holiday Function

Provides frost protection or overheat 
protection during periods of absence (holiday). 

•  For permanent frost protection select 

 and press (OK).  

  is shown in permanent frost protection.

•  For holiday frost protection press (OK) again, ‘no’ will blink.
Press  

 button to increase number of hours (1-24)/days (1-99), 

and press (OK) to confirm. Thermostat is now in holiday mode.
The  

  will blink and will continue to blink until the timer ends.

It is possible to exit the holiday function by pressing and  
holding 

 for 2 seconds.

Boost Function

Brings the unit on irrespective of the 
programme or temperature setting for a 
predefined period.
Default is 30 minutes.
Can be used in Comfort, Auto, 
Night Set-Back mode.

Select   using    or    or directly using button 20. 

The time period in minutes will blink.
Use 

  or  

 to adjust time by increments of 10 minutes.

Press (OK) to confirm, the hourglass will begin to blink 
and countdown.
It is possible to exit boost function by pressing 

.

P

Programme Menu

Provides choice from 9 pre-programmed and 
4 user defined timed programmes.

Refer to following page.

Heating System 

Switch

Fan only / Off / Heating
Blue dot (B) / O / Red dot (R)

Boost / Low

II     /     I

Boost / Normal

II     /     I

Heating Selector 

Switch

Fan Only Speed 

Switch

(B)

(OFF)

(R)

EN

EN

Содержание Kickspace 500E ECO

Страница 1: ...E ECO INSTALLATION OPERATING MANUAL INSTALLATIE EN GEBRUIKSAANWIJZING PLEASE LEAVE THIS MANUAL WITH THE END USER LAAT DEZE INSTRUCTIES NA INSTALLATIE BIJ DE GEBRUIKER ACHTER EN NL Product code and ser...

Страница 2: ...ted on a clean and level floor area under the cupboard base and securely fitted The top of the support must be level with the lower edge of the cut out when fitted l Decide the position of the KICKSPA...

Страница 3: ...gin to blink 3 Use or to change the hour and press OK to confirm the minutes will then begin to blink 4 Use or to change the minutes and press OK to confirm the day number will then display 5 Use or t...

Страница 4: ...ve to the next half hour 6 When you reach the final segment 23 30 press OK to move to day 2 here you have the option to copy the same programme that you have just created or create an alternative prog...

Страница 5: ...f boost period 11 Behaviour indicator 3 led colours green orange and red visible through the plastic 12 Open window detection 13 Appears when in user setting menu 14 Comfort mode 15 Auto mode 16 Reduc...

Страница 6: ...ol with integrated thermostat N A manual heat charge control with room and or outdoor temperature feedback N A electronic heat charge control with room and or outdoor temperature feedback N A fan assi...

Страница 7: ...geeft aan dat het product niet als huishoudelijk afval mag worden behandeld maar apart moet worden gesorteerd Wanneer het einde van zijn nuttige levensduur is bereikt dient u het bij een inzamelingsp...

Страница 8: ...K om te bevestigen de minuten beginnen te knipperen 4 Gebruik of om de minuten te wijzigen en druk op OK om te bevestigen de dagen worden dan weergegeven 5 Gebruik of om de dag te wijzigen waarbij maa...

Страница 9: ...vervolgens op OK om de parameterinstelling te wijzigen Wanneer de waarde begint te knipperen gebruik dan of om de waarde aan te passen Druk op OK om te bevestigen Nadat de parameters zijn ingesteld g...

Страница 10: ...tijd van boost periode 11 Gedragsindicator 3 led kleuren groen oranje en rood zichtbaar door de kunststof behuizing 12 Detectie open raam 13 Verschijnt in het menu gebruikersinstelling 14 Comfortmodus...

Страница 11: ...n dagtimer nee elektronische kamertemperatuurregeling en weektimer ja Andere besturingsopties kamertemperatuurregeling met aanwezigheidsdetectie nee kamertemperatuurregeling met detectie van open rame...

Отзывы: