COLUMN
model overview
/ connection dimensions
Dimension and Mounting Quick Reference
Myson Inc./Rettig USA 45 Krupp Drive, P.O. Box 1460, Williston, VT 05495 www.mysoncomfort.com
0
5
Length equals the number of
sections times 2"
Example: 56 sections times 2"
equals 112"
2"
1"
1 1/4"
1 1/4"
All tappings are 1/2" BSPT
C
L
LKD16AN
C
L
1 3/4"
1 3/4"
Shown with DAV12 and
LKD16AN valves. See page 1
2
for additional valve choices .
DAV12
4"
3/4"
1-3/16"
2-
5/
16"
3-
1/
4"
5/8"
2
"
1/2"
Position 2
Position 1
Column Radiator Wall Brackets
4 Column
5
1
/
2
"
3 Column
4"
2 Column
2
1
/
2
"
Pipe centers from finished wall are
dependent on which mounting slot is
selected on the mounting bracket and
the number of columns.
2 Column 3 Column 4 Column
Position 1 Min
:
2
1
/
2
"
3
1
/
4
"
4"
Position 2 Max
:
2
7
/
8
"
3
5
/
8
"
4
3
/
8
"
To obtain pipe centers using Myson
valves multuply the number of
sections by 2" and add 3.5".
Example:
A 12 section radiator would
be 12 x 2"+ 3.5" = 27.5"
MYSON COLUMN RADIATOR
ROUGH -IN SPECIFICATIONS