background image

02

COLUMN

.

MYSON COLUMN

 

radiator

'

s

 aesthetically sophisticated 

d

esign 

was conceived  for

 

technologically 

superior

 heating.  The

ir design form makes them suitable for a wide range 

of architectural applications from retro to modern.

Contents/Warranty

03
04

05

06

07
08

12

Kontec 

Basics

Myson, Inc. Limited Warranty

Myson, Inc warrants the following products against defects in material and workmanship to the original owner for the 

duration listed from date of installation or three months after date of shipment, whichever comes first.

The remedy in all cases shall be to repair or replace the product at Myson’s discretion upon verification of a factory defect. If 

replacement is required, and an exact replacement product is no longer available, Myson reserves the right to furnish a 

similar product of equal value.

NO REMOVAL, SHIPPING OR INSTALLATION EXPENSES ARE REIMBURSIBLE

The original purchaser is responsible for determining the suitability of the Myson product for their installation. Installation 

and troubleshooting should be performed by a competent technician with knowledge of hydronic heating and/or basic 

electricity. 
Damages occurring during shipment, transit, storage or handling, abuse, neglect, accident, misapplication, incorrect power 

line voltage, 

mproper water source or connection, fire, flood or other Acts of God are not covered. Freight damage claims 

MUST be made within 10 days of receipt from Myson. No Exceptions. 

 STEEL PANEL RADIATORS

 

-- 

SELECT, T6, DÉCOR, COLUMN AND BENCH 

The duration of warranty for steel panel radiators is 5 Years.

 

Painted finishes will not peel or flake from the surface of the radiator

The body of the radiator and its welded joints will not leak when the

 product is properly installed and maintained

according to Myson's instructions.

What is not covered:

Rust occurring from improperly sealed threaded connections or

 

oxygen corrosion

Electrolytic corrosion caused by failure to flush the system properly

 after initial installation

Contents

What is covered:

Important information

   

Product description 
Model overview / connection dimensions

 

Piping & rough-in

W

all

 bracket position

 information

 

Optional Floor bracket information

 

Heating outputs / weights / water content

 

Piping arrangements
Valve selection 

Heat output factors / System start - up

13

9

 - 

1

0

11

Содержание BENCH

Страница 1: ...01 11 2011 MYSON heatingthroughinnovation Column Radiator Series Installation Technical Guide...

Страница 2: ...competent technician with knowledge of hydronic heating and or basic electricity Damages occurring during shipment transit storage or handling abuse neglect accident misapplication incorrect power lin...

Страница 3: ...son D cor Steel Panel Radiator please follow all the instructions carefully Step 3 Failure to follow these instructions will invalidate the manufacturer s warranty APPLICATION Myson radiators are only...

Страница 4: ...pressure 145 psi Maximum operating temperature max 72psi max 04 Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com P R O D U C T D E S C R I P T I O N 12 3045 Ove...

Страница 5: ...e 12 for additional valve choices DAV12 4 3 4 1 3 16 2 5 16 3 1 4 5 8 2 1 2 Position 2 Position 1 Column Radiator Wall Brackets 4 Column 5 1 2 3 Column 4 2 Column 2 1 2 Pipe centers from finished wall...

Страница 6: ...radiator valves are available for automatic temperature control of individual radiators available in 3 body patterns with or without thermostatic head sensor use in conjunction with LKD or FF Myson In...

Страница 7: ...ow 25 32 13 16 7 16 3 4 1 1 2 15 32 Wall Bracket Wall Radiator A Distance between Wall Center Wall Bracket Radiator Bracket 25 32 7 16 17 32 21 2 31 4 4 13 16 7 16 1 5 8 27 8 3 5 8 43 8 2 column 3 col...

Страница 8: ...for top of upright Height of Upright Order Code 18 24 30 Base Plate Cover Height of Radiator 12 18 24 50 20046 50 20061 50 20076 COVERSK Floor Bracket SK Optional COLUMN Floor Bracket Detail 49 16 Mys...

Страница 9: ...12 6 41 4 3006 6 2200 16 8 55 2 4008 8 2200 20 10 69 0 5010 10 2200 24 12 82 8 6012 12 2200 30 15 103 5 7515 15 2200 Water Content gals 1 68 2 24 2 80 3 36 3 92 5 00 2 10 2 80 3 50 4 20 4 90 3 00 4 0...

Страница 10: ...80 85 x 21 x 14 6 190 9182 23 06 6180 93 x 19 x 14 5 186 8895 23 05 6200 Water Content gals 3 75 4 49 4 41 5 28 4 52 6 50 5 34 7 64 5 90 Dimensions in LxHxW 93 x 21 x 14 6 205 10383 23 06 6200 8 42 3...

Страница 11: ...nc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com 11 The following drawings are general examples Consult a certified heating professional for your specific application...

Страница 12: ...andles FF16WAC is adjustable for balancing FF16LAC is fixed open but can be closed for service TRV thermostatic radiator valves are available for automatic temperature control of individual radiators...

Страница 13: ...esh water oxygen into the system attacking radiators internally SYSTEM START UP MAINTENANCE CLEANING 1 Once operating avoid the introduction of fresh water and oxygen to the system to prevent corrosio...

Страница 14: ...NOTES Notes Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com 14...

Страница 15: ...NOTES Notes Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com 15...

Страница 16: ...heatingthroughinnovation MYSON Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com COLUMN 3 2014...

Отзывы: