The MyGate Q71A Control Board Installation Manual : Printed 06/11/2012 14:18
10
To Use in Closing Cycle
To connect power to Transmitter Unit
Use 1 core wire to connect AC+ on photocell
Transmitter Unit (TX) to Terminal 12.
Use 1 core wire to connect AC- on photocell
Transmitter Unit (TX) to Terminal 13
To connect power to Receiver Unit
Use 1 core wire to connect AC+ on photocell
Receiver Unit (RX) to Terminal 12
Use 1 core wire to connect AC- on photocell
Receiver Unit (RX) to Terminal 13
To connect the relay function to Control Board
Use 1 core wire to connect 3
rd
terminal (looking
from left to right) on photocell Receiver Unit (RX)
to Terminal 15
Use 1 core wire to connect 4th terminal (looking
from left to right) on photocell Receiver Unit (RX)
to Terminal 14
IMPORTANT: Please place a link between terminals 16 and 17
To Use in Opening Cycle
To connect power to Transmitter Unit
Use 1 core wire to connect AC+ on photocell
Transmitter Unit (TX) to Terminal 12
Use 1 core wire to connect AC- on photocell
Transmitter Unit (TX) to Terminal 13
To connect power to Receiver Unit
Use 1 core wire to connect AC+ on photocell
Receiver Unit (RX) to Terminal 12
Use 1 core wire to connect AC- on photocell
Receiver Unit (RX) to Terminal 13
To connect the relay function to Control Board
Use 1 core wire to connect 3
rd
terminal (looking
from left to right) on photocell Receiver Unit (RX)
to Terminal 17
Use 1 core wire to connect 4th terminal (looking
from left to right) on photocell Receiver Unit (RX)
to Terminal 16
IMPORTANT: Please place a link between terminals 14 and 15