Installation Manual for F36 and F54 Ceiling Fans
7
iNSTALLiNg WALL CONTROL (ROTARy) SWiTCH
1. With electrical power still disconnected, install fan switch control wiring to desired location on wall.
Wall plates are not supplied so that the customer can choose a style suitable for their specific situation
(wall
plates should be supplied by the installer).
2. Ensure wiring connections are as shown in Fig 9. The Active (Red) supply wire must be connected to
terminal “C” on the rotary switch mechanism. Return switched wire to ceiling fan to be connected from
terminal ˝1˝ on the switch mechanism to ˝L˝ terminal on the connector block.
3. Fit the switch mechanism into a face plate (not supplied) and attach to wall. Then snap on the Switch
knob to the spindle of the switch mechanism protruding out from plate. Switch knob ‘0’ marking should
be in the 12 o’clock position.
4. Restore electrical power to the ceiling fan by turning the electricity on at the main fuse box.
5. Check the operation of the fan by rotating the control through the four positions marked 0 – III
(“0” position is OFF) (Figure 12).
Figure
11
Figure
12
tO reduce tHe rIsk OF FIre Or electrIc sHOck, dO nOt use sOlId state
Or dIMMer-tyPe sPeed cOntrOls WItH tHIs Fan. use OF cOntrOls nOt
aPPrOVed by MyFan May PerManently daMage yOur Fan and WIll VOId
tHe Warranty.
N
L1
L
Supply Cable
Isolating
Switch
Red Wire
(Active)
Grn/Yel Wire
(Earth)
Black Wire
(Neutral)
Red Wire
(Motor Active)
Rotary Switch
3
C
1
2
Red
Br
own
Purple
Capacitor
Grn/Yel Wire
(Earth) from
Hanger Bracket
Grn/Yel Wire
(Earth) from Fan
Blue Wire
(Neutral)
Orange Wire
(Light Active)
Hanger Ball
Brown Wire
(Motor Active)
Terminal Block
(on Hanger Bracket)
To Terminal
Block
To Terminal
Block L
To Terminal
Block N
= OFF = FAST = MED = SLOW
IMPOrtant:
Fan installation must be
completed including the
installation of the fan
blades, before testing of
the controls.
Switch knob