ELECTRICAL

Hazardous Voltage. Can cause severe or

fatal electric shock.

Pump is supplied with a grounding con-

ductor and ground ding-type attachment plug. To reduce risk
of electric shock, be certain that it is connected only to a
properly grounded, grounding type receptacle. Ground termi-
nal on pump cord plug is provided for your protection. DO
NOT REMOVE!
A ground fault circuit interrupter is recommended for use with
any electrical appliance submerged in water. For installation
of such a circuit, consult a licensed electrician.

OPERATION / MAINTENANCE

Risk of electric shock. Before attempting to

check why unit has stopped operating, disconnect power
from unit. Do not handle pump with wet hands or when
standing on wet or damp surfaces, or in water.

Risk of flooding.

If a flexible discharge hose

is used, pump may move when motor starts. If the switch hits
the side of the sump, the switch may stick and prevent the
pump from starting. Make sure the pump is secured so it
cannot move around in sump.

Risk of sudden starts. The pump motor is

equipped with automatic resetting thermal protector and
may restart unexpectedly.

1.

If protector trips, motor may be overloading. Check for
the following problems:
A. Not enough back pressure in discharge pipe.
B. Voltage too high or too low.
C. Wires to motor too small.
D. Motor incorrectly connected to power supply wires.
E. Defective motor.

2.

Shaft seal depends on water for lubrication and cooling.
Do not operate pump unless it is submerged in water as
seal may be damaged if allowed to run dry.

3.

Motor is equipped with automatic reset thermal protector.
If temperature in motor should rise unduly, switch will cut
off all power before damage can be done to motor. When
motor has cooled sufficiently, switch will reset automati-
cally and restart motor. If protector trips repeatedly,
unplug the pump and remove it; check for cause of diffi-
culty. Low voltage, long extension cords, clogged
impeller, very low head or lift, etc., could cause cycling.

4.

Pump will not remove all water. If manually operated
pump is operating and suddenly no water comes out dis-
charge hose, shut off unit immediately. Water level is
probably very low and unit has broken prime.

CLEANING AND REPLACING
IMPELLER

1.

Unplug the pump.

2.

Loosen the clamps on the hose and clamp assembly.

3.

Slide the hose and clamp assembly up on the discharge
pipe and remove the pump from the sump.

4.

Turn the pump upside down and remove the screw securing
the pump screen.

5.

Loosen and remove the clamp that holds the lower and
upper pump housings together. Remove the lower pump
housing.

6.

Hold the motor shaft with a screwdriver in the slot on the
bottom end of the shaft, and unscrew the impeller off of the
shaft.

7.

Clean and replace the impeller as necessary.

8.

Reverse Steps 1 through 6 above to replace the impeller
and reinstall the pump.

9.

Fill the sump with water and run the pump through one
complete cycle to make sure that it is correctly reassembled
and operating as it should.

AUTOMATIC FLOAT SWITCH -
INSTALLATION

1.

Install pump following installation and operating instructions.

2.

Automatic float switch is sealed and factory adjusted for
most home sumps. See Page 1 for switch settings.

3.

Be sure that horizontal float switch clearance is 8". For
best performance of pumps with tethered switches, sump
diameter and sump depth should be at least 14".

4.

Plug piggyback switch cord into 115V AC outlet. Then,
plug pump into piggyback switch cord. Do not allow cord
to interfere with float control motion or to drape over pump
motor. With electrician's tape or cable ties secure cord to
discharge pipe for cord protection.

FLOAT SWITCH - 
OPERATIONAL CHECK 

1.

Fill the sump with correct amount of water to check oper-
ation and tightness of connections. During the first auto-
matic cycle, it may take 30 seconds or more before pump
is primed and pumping. Pump will start as indicated in
the “Motor, Switch and Cord” Specifications Table, Page
1.

2.

Check turn-off position. Pump will stop approximately as
indicated in the “Motor, Switch and Cord” Specifications
Table, Page 1.

3.

If pump does not operate check electrical service.

NOTICE:

Float switch tether length is set at factory. It is

3" (76mm) for SP75 Series pumps. Do not change tether
length of float switch. Float must swing through its com-
plete arc without interference.

3

3"

(76 mm)

Float Switch Tether Length

Содержание SP75 Series

Страница 1: ...ion limitations and potential hazards 2 Disconnect power before servicing 3 Release all pressure within system before servicing any component 4 Drain all water from system before servicing 5 Secure discharge line before starting pump An unse cured discharge line will whip possibly causing personal injury and or property damage 6 Check hoses for weak or worn condition before each use making certain...

Страница 2: ...sump pit of small stones and gravel which could clog pump Keep pump inlet screen clear NOTICE Do not use ordinary pipe joint compound on plastic pipe Pipe joint compound can attack plastics 4 Install discharge plumbing When using rigid pipe use plastic pipe Slip rubber coupling over pump discharge Install and tighten first clamp Place second clamp loosely over cou pling Slip coupling over discharg...

Страница 3: ...ter comes out dis charge hose shut off unit immediately Water level is probably very low and unit has broken prime CLEANING AND REPLACING IMPELLER 1 Unplug the pump 2 Loosen the clamps on the hose and clamp assembly 3 Slide the hose and clamp assembly up on the discharge pipe and remove the pump from the sump 4 Turn the pump upside down and remove the screw securing the pump screen 5 Loosen and re...

Страница 4: ...10801 10801 5 Housing Clamp 1 15146 15146 15146 6 Impeller 1 PS105 1P PS105 1P PS105 1P 7 Lower Pump Housing 1 12084 12084 12084 8 Pump Screen 1 12924 12924 12924 9 Screw Panhead 4327 4327 4327 10 Hex Nut 1 U36 105SS U36 105SS U36 105SS 11 Automatic Float Switch Assembly 1 PS17 109 PS17 111 12 Screw Panhead 1 U30 971SS U30 971SS 13 Switch Cord Clamp 1 CC0030 13 CC0030 13 14 Nut Acorn SS 1 U36 203S...

Страница 5: ...ch Pump won t shut off Defective float switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle in piping Float obstructed Remove obstruction Pump operates but Low line voltage If voltage under recommended minimum check size of wiring from main delivers little or no water switch on property If OK contact power company or hydro authority Something caught in im...

Страница 6: ...ranty is void Your only remedy and F E MYERS s only duty is that F E MYERS repair or replace defective products at F E MYERS s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired Thi...

Страница 7: ...urer de couper le courant qui l alimente 3 Dissiper toute la pression du système avant d intervenir sur un composant du système 4 Avant d intervenir sur le système vider toute l eau qu il contient 5 Immobiliser le tuyau de refoulement avant de démarrer la pompe Un tuyau de refoulement non immobilisé se mettra à fouetter et risquera d éclater ou d entraîner des dégâts matériels et ou causer des ble...

Страница 8: ... le gravier du fond du puisard pour qu ils ne bouchent pas la pompe La crépine d aspiration de la pompe doit toujours être débarrassée des corps étrangers REMARQUE Ne pas utiliser de pâte pour raccords filetés sur les tuyaux en plastique car elle risque d attaquer le plastique 4 Brancher le tuyau de refoulement Si on décide d utiliser des tuyaux rigides utiliser des tuyaux en plastique Glisser le ...

Страница 9: ...uyau souple et colliers 3 Glisser l ensemble de tuyau souple et colliers vers le haut sur le tuyau de refoulement et sortir la pompe du puisard 4 Tourner la pompe à l envers et déposer la vis qui immobilise la crépine de la pompe 5 Desserrer et déposer le collier qui retient les corps inférieur et supérieur de la pompe Sortir le corps inférieur de la pompe 6 Tenir l arbre du moteur en plaçant un t...

Страница 10: ...146 6 Impulseur 1 PS105 1P PS105 1P PS105 1P 7 Corps inférieur de la pompe 1 12084 12084 12084 8 Crépine de la pompe 1 12924 12924 12924 9 Vis à tête cylindrique large 4327 4327 4327 10 Écrou à six pans 1 U36 105SS U36 105SS U36 105SS 11 Interrupteur à flotteur automatique 1 PS17 109 PS17 111 12 Vis à tête cylindrique large 1 U30 971SS U30 971SS 13 Collier du cordon électrique du flotteur 1 CC0030...

Страница 11: ...arrête pas Interrupteur à flotteur défectueux Remplacer l interrupteur à flotteur Refoulement obstrué Sortir la pompe du puisard puis la nettoyer ainsi que les tuyaux obstruction dans le tuyau Flotteur obstrué Enlever l obstruction La pompe fonctionne Tension de ligne basse Si la tension est inférieure à la tension minimale recommandée vérifier le mais débite très peu calibre du câblage côté disjo...

Страница 12: ...cours de l Acheteur et la seule responsabilité de F E MYERS consistent à réparer ou à remplacer au choix de F E MYERS les produits qui se révéleraient défectueux L Acheteur s engage à payer tous les frais de main d œvre et d expédition du produit couvert par sa garantie et de s adresser au concessionnaire installateur ayant procédé à l installation dès qu un problème est découvert pour obtenir un ...

Страница 13: ...zar trabajos de reparación y mantenimiento 3 Libere toda la presión dentro del sistema antes de realizar tra bajos de reparación o mantenimiento en cualquiera de los com ponentes 4 Drene toda el agua del sistema antes de realizar trabajos de reparación o mantenimiento 5 Asegure la línea de descarga antes de arrancar la bomba Una línea de descarga no asegurada podrá dar una sacudida y posiblemente ...

Страница 14: ...ga la criba de admisión de la bomba despejada AVISO No use un compuesto común para juntas de tuberías en una tubería de plástico El compuesto para juntas de tuberías puede atacar al plástico 4 Instale la fontanería de descarga Cuando use un tubo rígido use un tubo de plástico Deslice el empalme de caucho sobre la descarga de la bomba Instale y apriete la primera abrazadera Coloque la segunda abraz...

Страница 15: ...amente El nivel del agua está probablemente muy bajo y la unidad no está cebando LIMPIEZA Y REEMPLAZO DEL IMPULSOR 1 Desenchufe la bomba 2 Afloje las abrazaderas en la unidad de manguera y abrazaderas 3 Deslice la unidad de manguera y abrazaderas hacia arriba en la tubería de descarga y saque la bomba del sumidero 4 Invierta la bomba y saque el tornillo que sostiene la criba de la bomba 5 Afloje y...

Страница 16: ...azadera de caja 1 15146 15146 15146 6 Impulsor 1 PS105 1P PS105 1P PS105 1P 7 Caja de la bomba inferior 1 12084 12084 12084 8 Criba de la bomba 1 12924 12924 12924 9 Tornillo cabeza de cono achatado 4327 4327 4327 10 Tuerca hexagonal 1 U36 105SS U36 105SS U36 105SS 11 Ensamblaje del conmutador automático de flotación 1 PS17 109 PS17 111 12 Tornillo cabeza de cono achatado 1 U30 971SS U30 971SS 13 ...

Страница 17: ...mba no se apaga Conmutador de flotación Cambie el conmutador de flotación defectuoso Descarga limitada Saque la bomba y limpie la bomba y la tubería obstáculo en la tubería Flotador obstruido Elimine la obstrucción La bomba funciona pero Línea de baja tensión Si la tensión se encuentra por debajo del mínimo recomendado verifique el entrega poco o nada de tamaño de los cables desde el conmutador pr...

Страница 18: ...do de lo contrario la garantía quedará anulada Su único recurso y la única obligación de F E MYERS es que F E MYERS repare o reemplace los productos defectuosos a juicio de F E MYERS Usted deberá pagar todos los cargos de mano de obra y de envío asociados con esta garantía y deberá solicitar el servicio bajo garantía a través del concesionario instalador tan pronto como se descubra un problema No ...

Страница 19: ......

Страница 20: ......

Отзывы: