Installation
Relay & Sensor Board
eddi
has the option to install a Relay & Sensor Board (available separately), this allows for many different wiring
configurations and includes the following features:
•
Two independent multifunction relays (16 Amp)
•
eSense input (isolated 230V detection for low tariff etc.)
•
Two temperature sensor inputs (PT1000)
The two relays can be independently set to for several different functions, or they can be set to operate as a pair. The relay
functions include:
•
Export Threshold
•
Import Threshold
•
Operate when heating
•
De-stratification pump control
•
Timed operation
•
Fault signal for BMS systems
Refer to
Application Examples
in this guide and
Relays & Sensors
Menu
for practical examples and function descriptions.
Relay & Sensor Board Installation
The Relay & Sensor Board is installed by plugging it into the
eddi
main circuit board using the three plastic spacers included
with the Relay & Sensor Board.
The flexible ribbon cable is then pushed into to black connector to the left side of the display on the top
eddi
circuit board.
28
eddi
operation and installation manual
A3210
A3210