Menus
Advanced Menu Options
Description
Channel…
RF Channel:
Sets the radio frequency channel number used when
linking other devices - See
Linking Devices
(page 21)
Reset Settings…
Clear all linked device settings. See
Linking Devices
(page 21)
CT Inputs…
CT 1:
Set the function of CT1 input
Note: This must be set to 'Disabled' if the Grid Sensor
is connected to
Harvi
CT 2:
Set the function of CT2 input
Test…
Heater 1…
Test Heater 1 is connected and working
Heater 2…
Test Heater 2 is connected and working
Grid Sensor (CT1)…
Test Grid Sensor for installation errors
Generation Sensor (CT2)…
Test signal from Generation Sensor
Passcode…
The code required to access the Advanced menu
Restore
Settings…
Restore Yesterday
Restore the configuration from the previous day
Clear Data
Clear all savings data from memory
Factory Reset
Restore configuration to factory defaults (savings data
are unaffected unless Clear Data is also selected)
Confirm
Confirm restore options and re-boot device
Relay & Sensor Menu
Relay & Sensor Board Menu
(if installed)
Description
Relays &
Sensors…
Temperatures…
Set Limit:
The target temperature for when using a PT1000
temperature probe connected to PT1/PT2
PT1 corresponds to Heater 1, PT2 is for Heater 2
Hysteresis:
Sets the temperature drop required from Set Limit,
before heating resumes
Readings:
Current temperature readings of the probes
Relay 1…
Disabled
Disable Relay 1 control (relay is always off)
Export…
On Threshold:
When export power exceeds this threshold, the relay
will operate
Off Threshold:
When the export power is under this threshold the
relay is switched off
Inc Diverted:
Surplus power currently being diverted to the heater
will be included as export for the thresholds above
Min On Time:
When the On Threshold is exceeded and the Relay
switches on, it will remain on for at least this time
after the export drops below the Off Threshold
Min Off Time:
When the export power exceeds the On Threshold
the relay will operate only if it has been off for this
amount of time
Import…
On Threshold:
When import power exceeds this threshold, Relay 1
on the Relay & Sensor Board will operate
Off Threshold:
When the import power is under this threshold the
relay is switched off
Min On Time:
When the On Threshold is exceeded and the Relay
switches on, it will remain on for at least this time
after the import drops below the Off Threshold
Min Off Time:
When the import power exceeds the On Threshold
the relay will operate only if it has been off for this
amount of time
Heating…
Heating 1
Operates Relay 1 when Heater 1 output is live
Heating 2
Operates Relay 1 when Heater 2 output is live
16
eddi
operation and installation manual