Dehumidifier inside the room to be dehumidified

The outlet of the humid air is connected to the outside air. The process air inlet has two connecting pieces to create 
pressure equalisation between the room to be dehumidified and the ambient air. The right inlet connecting piece 
should be connected to the outside air with a pipe. The left inlet connecting piece can be left open if the dehumidified 
room is well sealed from the surroundings. If the room to be dehumidified is not adequately sealed from the outside 
air, then throttling should be installed on the left inlet connecting piece. If the inlet drawing air in from the room is 
throttled, the dehumidifier creates overpressure in the room, which prevents the outside air from flowing into the 
room to be dried. Make sure that the dry air can blow out freely.  

Air humidifier outside the room to be dehumidified: The outlet for the dry air is connected via a pipe to the room to 
be dehumidified. If particularly low moisture content is required, then a process air inlet should also be connected to 
the room. If the room to be dehumidified is not sealed adequately, then overpressure should be created by throttling 
the operating air flow of the process air from the room to be dehumidified.

3. OPERATION

1.   Check whether both air equalisation throttles are open, if they are present, and whether the air flows in 

the pipes are not obstructed in any way.

2.   Make sure the filter is fitted properly.
3.   Check whether the input fuse has the strength called for in the datasheet (16 A).
4.   Plug in the connector into a 16 A power outlet protected with a residual current operated circuit breaker.
5.   Before switching on, read the hours of operation as well as the energy meters in order to use them to 

prepare an invoice after the drying operation.

6.   Start the dehumidifier by pressing switch B.

 You have a choice between permanent dehumidification operation (ON) and regulated operation via an 
external hygrostat sensor (accessory). If this is the case, set the function to “AUTO”.

A.  Operating hours meter 

B.  On/Off/AUTO (main switch)

C.  Power cord 

D.  Hygrostat connection 

   Strong esslectricity! 
   Do not touch it!!

E.  Energy meter (kWh) 