No.QT33-04003A
―
10
―
6. Wiring and Install condition
6-1. Wiring for motor lines and power lines
・
When wiring, surely wire the protect earth line at first.
・
Install noise filter at power input where noise sources exist near the driver.
・
This driver has fuse inside, but use no-fuse-breaker or circuit protector of the capacity of below table for
safety.
6-2. Wiring of motor line
・
Using shield wire can depress the radiant noise in case that the unnecessary radiation causes troubles.
6-3. Wiring of signal line
If the following procedure is not made, there may be a cause of incorrect operation.
・
Use bigger cable than AWG28 which suits with the connector.
・
Use twisted pair line or shield line.
・ ①
of twisted pair wiring diagram is recommended in case of twisted pair line but select and use a
suitable diagram of
②
to
④
depending on cable and environment. However do not wire as
○
A
to
○
C
Driver
model
Current
capacity
INS20-010
2
A
INS20-210
3
A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com