5. No scratch in case of scabbing;
6. Make a water replenishing care in 10 days

Ⅷ.

Warranty Policy

The warranty of equipment is one year from the date of supply. During the warranty period, we

undertake to repair free for the equipment supplied against all manufacturing and workmanship

defects.

The standard of operation and environment should comply with the product specification and

user manual.

The warranty does not extend to any equipment that:

a. Malfunctions caused by abused operation

b. Malfunctions caused by modification or repair by anyone except EASYLASER or not

authorized by EASYLASER; from which EAYLASER original serial number tag or product

identification markings have been altered or removed

c. Malfunctions caused by other artificial factors like move or tear down in proper motion, or

collision, etc.

d. Malfunction caused by uncontrollable natural force

d. Energy reduce caused by wet environment and dust

f. Consumable parts of the equipment: handpieces.

Содержание HR-T350

Страница 1: ...Page 1 in 12 pages Please read the instructions before use Brief Introduction E light applies three core technology IPL RF and epidermis cooling It combines the USER MANUAL...

Страница 2: ...hermolysis effect Since light energy is far below conventional IPL the pigment tissue and vascular pathological tissue of the corium and epidermis would absorb more energy without injuring the epiderm...

Страница 3: ...ense pulsed light source xenon lamp B Reflector and filter C Sapphire wave guide 2 Technique Specification Light Energy 1 50J cm2 RF energy 1 25J SR Spectra 530 1200nm Cooling water air semi conductor...

Страница 4: ...ing the gel evenly 2 3mm on the skin Effect light guide cooling anaesthetisin Attention no coating on eyes eyebrows lips 2 6 Eye protection Operator wear the safety goggles Patient close the eyes wear...

Страница 5: ...ction before for similar operation fill the Client File concretely Adjust the parameters on the basis of full acquaintance of the condition of operatee Inform the operatee the possible reation in oper...

Страница 6: ...3 4 2 Double confirm there is no leaking of water circulation fold the protective cover by turning it right 3 5 Debugging 3 5 1 Make sure water and electric circuit is correct connected then turn on t...

Страница 7: ...e wanted treatment program by clicking 3 6 2 Operation Interface Operation Interface Treatment mode 3 groups of different parameters setting Pulse1 working time of the first pulse Pluses sub pulse wid...

Страница 8: ...amp is on but could not make shots start pause click start zimmer the handle and the capacitor charge automatically system will enter the treatment status when charge is ready Click stop escape from t...

Страница 9: ...Blackhead and oil comeout in 2 3 days and disappear in 7 days Parameter control Long pulse width short interval high energy 3 8 7 Winkle pouch black circle Light pain Parameter control Short pulse wi...

Страница 10: ...t by improper handling Operators should keep vigilant and take necessary protection measures according to the manual Operatee Carry out the treatment in the professional treatment room take effective...

Страница 11: ...wer therefore do not dismantle the backboard without under supervising by our technicians Do not move the equipment by pulling the handpiece Do not use the equipment in inflammable and explosive envir...

Страница 12: ...tion and user manual The warranty does not extend to any equipment that a Malfunctions caused by abused operation b Malfunctions caused by modification or repair by anyone except EASYLASER or not auth...

Отзывы:

Похожие инструкции для HR-T350