![MyBinding Plockmatic FTR 200 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/mybinding/plockmatic-ftr-200/plockmatic-ftr-200_service-manual_1861757058.webp)
T
rouble-
shooting
FTR-4-13
12 February 2007
FTR-502
Fault Code FTR-502, indicates that the blowers (FTR-M5/M6) do not respond.
Initial Actions
Check placement of blowers.
Make sure blowers are installed correctly.
Procedure
Enter the Service mode and select blowers Trimmer (FTR-M5/M6) in check motors.
Do the blowers work?
Y
N
Go to FTR-014 fault code.
Replace PCB.
FTR-503
Fault Code FTR-503, indicates that the stacker is full. If fault occurs erronous, see FTR-204.
Содержание Plockmatic FTR 200
Страница 2: ...TRIMMER FTR 200 SERVICE MANUAL 12 February 2007 Subject to change ...
Страница 3: ...Page intentionally blank ...
Страница 7: ...Page intentionally blank ...
Страница 9: ...Page intentionally blank ...
Страница 19: ...Page intentionally blank ...
Страница 43: ...Page intentionally blank ...
Страница 45: ...Page intentionally blank ...
Страница 59: ...FTR 4 14 Page intentionally blank ...
Страница 61: ...Page intentionally blank ...
Страница 65: ...FTR 6 4 29 November 2006 6 1 3 OUTFEED VIEW FTR Q6 FTR M2 FTR M1 ELECTRICAL COMPONENT LIST ...
Страница 67: ...Page intentionally blank ...
Страница 68: ...Detailed description FTR 6 7 29 November 2006 6 2 BOARD STRUCTURE 6 2 1 BLOCK DIAGRAM Interlock magnet ...
Страница 71: ...Page intentionally blank ...
Страница 77: ...Page intentionally blank ...
Страница 78: ...FTR Wir 1 29 November 2006 Wiring WIRING Trimmer See pocket at rear of manual for wiring diagrams ...
Страница 79: ...Page intentionally blank ...