FTR-4-12
12 February 2007
FAULT CODE DESCRIPTIONS
FTR-204
Fault Code FTR-204, indicates that at “initialization” or during Run, the Outfeed sensor Trimmer (FTR-
Q6), was blocked exceeding timeout.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Outfeed sensor Trimmer (FTR-Q6) is installed correctly.
Ensure that the Outfeed sensor Trimmer (FTR-Q6) is clean.
Procedure
Enter the Service mode and select Outfeed sensor Trimmer (FTR-Q6) in check sensors. Block, then unblock, the FTR-Q6 with
a sheet of paper.
The Outfeed sensor Trimmer (FTR-Q6) sensor indicates :1 when the sensor is blocked and :0 when
the sensor is not blocked.
Y
N
Go to FTR-017 fault code.
Make sure that nothing interferes with the paper path.
FTR-401
Fault Code FTR-401, indicates that the Trim bin is full, or that the Trim bin full sensor FTR-Q8 is
faulty.
Procedure
Is there something blocking the Trim bin full sensor FTR-Q8?
Y
N
Go to FTR-018 fault code.
Remove the object and empty the Trim bin.
FTR-501
Fault Code FTR-501, indicates that the Trim bin is full, or that the Trim bin full sensor FTR-Q8 is
faulty.
Procedure
Is there something blocking the Trim bin full sensor FTR-Q8?
Y
N
Go to FTR-018 fault code.
Remove the object and empty the Trim bin.
FTR-203
Fault Code FTR-203, indicates that during Run, the Outfeed sensor trimmer (FTR-Q6), was not
blocked within timeout.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Outfeed sensor trimmer (FTR-Q6) is installed correctly.
Ensure that the Outfeed sensor trimmer (FTR-Q6) is clean.
Procedure
Enter the Service mode and select Outfeed sensor trimmer (FTR-Q6) in check sensors. Block, then unblock, the FTR-Q6 with
a sheet of paper.
The Outfeed sensor trimmer (FTR-Q6) sensor indicates :1 when the sensor is blocked and :0 when
the sensor is not blocked.
Y
N
Go to FTR-017 fault code.
Make sure that nothing interferes with the paper path.
FTR-205
Fault Code FTR-205, indicates that the Infeed shaft or the Outfeed compressing bracket not is in it’s
lower position or that control switch S2 or S3 is faulty.
Procedure
Is the Infeed shaft or the Outfeed compressing bracket lifted from it’s lower position?
Y
N
Go to FTR-016 fault code.
Lift Infeed/outfeed latch and make sure that the Infeed shaft and the Outfeed compressing bracket is in it’s lower position.
Содержание Plockmatic FTR 200
Страница 2: ...TRIMMER FTR 200 SERVICE MANUAL 12 February 2007 Subject to change ...
Страница 3: ...Page intentionally blank ...
Страница 7: ...Page intentionally blank ...
Страница 9: ...Page intentionally blank ...
Страница 19: ...Page intentionally blank ...
Страница 43: ...Page intentionally blank ...
Страница 45: ...Page intentionally blank ...
Страница 59: ...FTR 4 14 Page intentionally blank ...
Страница 61: ...Page intentionally blank ...
Страница 65: ...FTR 6 4 29 November 2006 6 1 3 OUTFEED VIEW FTR Q6 FTR M2 FTR M1 ELECTRICAL COMPONENT LIST ...
Страница 67: ...Page intentionally blank ...
Страница 68: ...Detailed description FTR 6 7 29 November 2006 6 2 BOARD STRUCTURE 6 2 1 BLOCK DIAGRAM Interlock magnet ...
Страница 71: ...Page intentionally blank ...
Страница 77: ...Page intentionally blank ...
Страница 78: ...FTR Wir 1 29 November 2006 Wiring WIRING Trimmer See pocket at rear of manual for wiring diagrams ...
Страница 79: ...Page intentionally blank ...