T
rouble-
shooting
FTR-4-11
12 February 2007
FTR-201
Fault Code FTR-201, indicates that during Run, the Infeed sensor (FTR-Q13), was not blocked within
timeout.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Infeed sensor (FTR-Q13) is installed correctly.
Procedure
Enter the Service mode and select Infeed sensor (FTR-Q13) in check sensors. Activate, then deactivate, the FTR-Q13.
The
Infeed sensor (FTR-Q13) indicates :1 when the sensor is activated and :0 when the sensor is deactivated.
Y
N
Go to FTR-016 fault code.
1. Make sure that the Exit guide bracket is installed as high as possible.
2. Make sure that nothing interferes with the paper path.
FAULT CODE DESCRIPTIONS
FTR-152
Fault Code FTR-151, indicates that the Interlock switch is faulty.
Initial Actions
Check fuse F2 on Transformer.
Enter the Service mode and check the Trimmer voltmeter.
Power ON and Power OFF the Trimmer (make sure that the Top cover interlock, and
the External Interlock Device interlock is interlocked).
Procedure
Measure the Interlock switch S9 and S10, and make sure that they are OK.
Are all two switches OK?
Y
N
Replace faulty switch.
Measure for continuity between J14-18 and J14-19, between J25-3 and J25-4.
Is there continuity in both cables?
Y
N
Replace wire harness.
Replace PCB.
FTR-202
Fault Code FTR-202, indicates that at “initialization” or during Run, the Infeed sensor (FTR-Q13), was
blocked exceeding timeout.
Initial Actions
Check fuse F2 on Transformer.
Make sure that the Infeed sensor (FTR-Q13) is installed correctly.
Procedure
Enter the Service mode and select Infeed sensor (FTR-Q13) in check sensors. Activate, then deactivate, the FTR-Q13.
The
Infeed sensor (FTR-Q13) indicates :1 when the sensor is activated and :0 when the sensor is deactivated.
Y
N
Go to FTR-016 fault code.
1. Make sure that nothing interferes with the paper path.
2. The trimmer knife is not in it’s home position, preventing the sets from the Booklet Maker to enter the Trimmer. Run trimmer
knife motor in check motors to reinstate the trimmer knife in it’s home position.
Содержание Plockmatic FTR 200
Страница 2: ...TRIMMER FTR 200 SERVICE MANUAL 12 February 2007 Subject to change ...
Страница 3: ...Page intentionally blank ...
Страница 7: ...Page intentionally blank ...
Страница 9: ...Page intentionally blank ...
Страница 19: ...Page intentionally blank ...
Страница 43: ...Page intentionally blank ...
Страница 45: ...Page intentionally blank ...
Страница 59: ...FTR 4 14 Page intentionally blank ...
Страница 61: ...Page intentionally blank ...
Страница 65: ...FTR 6 4 29 November 2006 6 1 3 OUTFEED VIEW FTR Q6 FTR M2 FTR M1 ELECTRICAL COMPONENT LIST ...
Страница 67: ...Page intentionally blank ...
Страница 68: ...Detailed description FTR 6 7 29 November 2006 6 2 BOARD STRUCTURE 6 2 1 BLOCK DIAGRAM Interlock magnet ...
Страница 71: ...Page intentionally blank ...
Страница 77: ...Page intentionally blank ...
Страница 78: ...FTR Wir 1 29 November 2006 Wiring WIRING Trimmer See pocket at rear of manual for wiring diagrams ...
Страница 79: ...Page intentionally blank ...