background image

 

: Zero key, press this key to return the display to 

zero if a small weight reading is left while 
unloaded/empty. 

VII. Counting function

 

Sampling 

1.

 

Press

     

key

the display will show

  “

Cnr10pcs

”  

 

(means sample size is 10 pcs) 

 

2.

 

Press the

         

key again and again, 10

20

50

100 pcs will 

appear in succession. Stop at the one you want to use.

 

3.

 

Put the exact quantity of samples as desired on the pan 

and press   

      ,

the determined sample size will be shown.

 

4.

 

Keep adding objects to be counted on the pan, the total 

number of the objects will be displayed.

 

 

If the unit weight is too small for the counting resolution,

 

“                ”

will be shown. 

VIII. Operations

 

● 

Weight units     

 

Press

       

key to choose the preset weight units 

g

ct

 & 

ozt. 

● 

Tare function

 

 

 

Put a container on the pan and press        when the display 

reading is stable.

 

The tare weight will be stored into memory 

and display will be brought to zero. “     ”  indication in the 

display will appear. The weight will be displayed as net 

weight. To cancel the tare mode, press     when no load 

on the weighing pan. 

  Tare range : Up to balance’s maximum capacity. 

● 

Zero function

 

Press            key to return the display to the center of zero if the 

zero Shifts during operation. 

  Zero range :    ± 2% of max. capacity 

. Error messages 

When the display shows “ 

               

 

it means that the 

balance is overloaded. Please remove the object from the pan immediately so 

as to avoid damage to the load sensor inside the balance.

 

 

Содержание iBalance 601

Страница 1: ...High Precision Balances iBalance 601 iBalance M01 LED Display Operation Manual KD TBED en V1 2 2005 ...

Страница 2: ...and zero display Press the key until the display shows 0 5d 1 0d 1 5d 2 0d 3 0d to power on press the key to select the range of zero tracking press to confirm Then it will display ZEr S or ZEr L press to select the zero display range ZEr S mean 0d ZEr L mean 3 0 d press to confirm then choose the Communication method by pressing the Key to rotate revolve Con send in succession stable send steadil...

Страница 3: ... your warranty 2 Do not drop or shock the scale and do not drop any item onto the scale or tray It may cause permanent damage Only operate the scale gently and place items on the tray gently Overloading the balance will damage the weighing sensor 3 Extreme temperature humidity fluctuations shocks and vibrations should be avoided at all times 4 If the scale will not be used for a long time please r...

Страница 4: ...fication model iBalance601 iBalanceM01 Maximum capacity 600g 1000g Display scale interval d 0 01g 0 01g Pan size Ø116mm Ø116mm Power source Rechargeable battery 6v 1 3Ah or 8 5v 0 2A AC DC adaptor V Explanation of display symbols 2 2D HEX negative sign 20 HEX blank 2E HEX decimal point UNIT 4 byte g 20 HEX 20 HEX 20 HEX 67 HEX kg 20 HEX 20 HEX 6B HEX 67 HEX ct 20 HEX 20 HEX 63 HEX 74 HEX ozt 20 HE...

Страница 5: ... 8 bits 3 Parity bit none 4 Stop bit 1 bit 5 Code ASCII DATA FORMAT HEAD1 HEAD2 DATA UNIT CR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 HEAD1 2BYTES HEAD2 2BYTES OL overload NT net weight mode ST stable US unstable DATA 8BYTE 6 Explanation Of Display Symbols Scale is in ZERO mode Scale is in TARE mode Scale needs recharging once this battery appear The display reading is in STABLE conditio...

Страница 6: ...lution will be shown VIII Operations Weight units Press key to choose the preset weight units g ct ozt Tare function 4 Put a container on the pan and press when the display reading is stable The tare weight will be stored into memory and display will be brought to zero indication in the display will appear The weight will be displayed as net weight To cancel the tare mode press when no load on the...