background image

Fitting Instructions

IMPORTANT!

This Step-by-Step guide should be retained after installation.

Atmos 

Vision

Thermostatic Bar Mixer Valve  

with Overhead

Содержание Atmos Vision

Страница 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Vision Thermostatic Bar Mixer Valve with Overhead...

Страница 2: ...uresystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTA...

Страница 3: ...ke sure ALL components are included before starting the installation Description Quantity BarMixerValve 1 Handset 1 VerticalRail 1 VerticalRailFixingBracket 1 Overhead 1 OverheadRail 1 HandsetHolder 1...

Страница 4: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Страница 5: ...MUSTbefittedinthesupply pipeworktopreventback flow Thepressureatboththehotandcoldwater suppliestothemixervalveshouldbethesame andtheinstallershouldensurethattheflowisnot affectedbyothertapselsewherein...

Страница 6: ...dsonanyof thepipefittings DONOTsolderfittingsnearthemixer valveasheatcandamagethevalvesseals Always flushthesystempriortoinstallingthevalve Beforeinstalling makesurethemixervalveiskept inacleanplaceto...

Страница 7: ...ingsure thesealingwashersareinplace screwtheunions ontothefittings Themixervalvemustbepositioned horizontallywiththehotsupplyonthelefthandside oftheoutlet Fig3 NOTE Ensureyouhavethecorrectvalvewiththe...

Страница 8: ...ve Securebytighteningthescrewontheside oftheverticalrailwiththesmallallenkeysupplied Fig4 7 Attachtheoverheadrailassemblytothewallplate Securebytighteningthescrewoneachsideofthe bracketrailwiththesmal...

Страница 9: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Страница 10: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Страница 11: ...MXGrouptoyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe componentandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotc...

Страница 12: ...CEPOLICY IntheeventofyouneedingtocontacttheMXGroup CustomerServiceDepartment thefollowing procedureshouldbefollowed 1 Beforetelephoningon08455052211theMXGroup CustomerServiceDepartmentyoushouldensure...

Отзывы: