background image

Marleton Cross Limited Trading as The MX Group,

 Alpha Close, Delta Drive,Tewkesbury Industrial Estate,Tewkesbury, Glos. GL20 8JF.

www.mx-group.com email: [email protected]

Customer Care: 0845 505 2211

6752B_10_14_GF

MX GROUP GUARANTEE SERVICE POLICY 

In the event of you needing to contact the MX Group Customer Care Department, the following 

procedure should be followed:

1.  

 Before telephoning on 0845 505 2211 the MX Group Customer Care Department  you 

should ensure you have the model number (printed on the valve) and date and proof of 

purchase your contact details and the postcode where the unit is installed.

2.  

The MX Group Customer Care Department will be able to tell you whether the fault can 

be simply rectified by the provision of a replacement part or arrange an on site visit by a 

Qualified Service Engineer.

3.  

If a service call is required it will be booked and the date of the call confirmed. You or a 

representative (over the age of 18 years) must be present during the entire engineers 

visit. The engineer will not be able to repair or replace or advise on parts or products not 

supplied as part of the product.

4.  

A charge will be made in the event of a service call aborted by you, but not by  us, or  

where a call under the terms of guarantee has been booked and failure is not related  to 

product supplied by MX Group (i.e Scaling and furring, incorrect water pressure, or  other 

plumbing problem unrelated to the normal function of the products).

5.  

If the product is no longer covered by the guarantee, a charge will be made for the site 

visit and for any parts supplied.

6.  

Service charges are based on the account being settled when the work is complete. 

The engineer will request payment. If this is not made on the day or settled within ten  

working days, and administration charge will be added.

SPARE PARTS

In the event that parts or maintenance is needed outside the guarantee MX will endeavour to help 

with this. Spare parts codes are given in the fitting instructions. By calling the Customer Care 

Department on 0845 505 2211 with the part number, they will be able to quote you to supply 

these parts, usually via our spare parts distributor. 

MX Atmos Select 6752B 09_14_GF.indd   16

24/10/2014   14:57

Содержание Atmos Select Round

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS Atmos Select 3 Way Thermostatic Concentric Mixer Valve with Riser Rail Overhead Customer Care 0845 505 2211 MX Atmos Select 6752B 09_14_GF indd 1 24 10 2014 14 56 ...

Страница 2: ...r temperature to a minimum of 52 C The water temperature at the inlet to the mixer valve must remain relatively constant when flow rate adjustments are made refer to the water heater operating manual to confirm compatibility with this mixer shower Inlet connections are female BSP threads which can be connected to 15mm or 22mm compression fittings not included SAFETY WARNINGS Layout and sizing of p...

Страница 3: ...ewateratapointnotlessthan25mmabovethe spill over level of the relevant bath shower tray or other fixed appliance A double check valve or similar MUST be fitted in the supply pipework to prevent back flow The pressure at both the hot and cold water supplies to the mixer valve should be the same and the installer should ensure that the flow is not affected by other taps elsewhere in the house It is ...

Страница 4: ...mixer valve is designed to work at the same hot and cold water pressures If this is not the case a flow controller disc with small holes can be fitted to the higher pressure supply to the valve This is best done by testing each one to find out which gives the best results Remember the mixer valve must installed in such a position that the maintenance of the TMV and the filters can be done after in...

Страница 5: ...s stated on the valve SITING OF THE SHOWER Having established the position of the mixer valve so that all controls can be comfortably reached whilst using the shower the handset and riser rail should be positioned at the side of the valve and the overhead rail directly above the valve Make sure any cables and pipework are not behind the required screw holes Consult the illustration below to make s...

Страница 6: ...mm and 110mm should be large enough to fit the mixer valve The valve should be fixed to the wall between 75mm and 90mm below the finished surface of the shower See Fig 5 2 The supply pipework can be plumbed from above or below but must finish at the suitable connections which should be at approximately 150mm centers See Fig 6 provision should be made for some adjustment on fitting the valve 3 Fit ...

Страница 7: ...These pipes must end in female connection so the wall outlet and overhead arm can be fitted If fitting as a 2 way valve the unused outlet must be blanked off using the BSP blank plug supplied 9 Once the mixer valve and wall outlet are fitted prior to fitting the trim plate ensure all connections are watertight This can be done by reconnecting the water supplies and check all connections To do this...

Страница 8: ...See Fig 12a b RISER RAIL FITTING FOR Square Style 1 Having established the position of the riser rail so that the showerhead can be comfortably reached whilst using the shower make sure any cables and pipework are not behind the screw holes See Fig 1 2 Remove caps and covers from brackets See Fig 2 3 For new installation Drill plug and screw For replacement installation locate bottom hole and scre...

Страница 9: ...les and pipework are not behind the screw holes See Fig 6 2 Remove end bracket cover to explore fitting point from upper of lower brackets See Fig 7 3 Drill and plug the wall and fix the lower bracket without the rail locator notch Fit rail to lower bracket Place the remaining bracket on top of the rail making sure the slot in the rail is located into the bracket notch Ensure the hole position is ...

Страница 10: ...without the double interlock hose attached WALL ARM FITTING 1 Establish position of wall arm to suit users requirements See Fig 12 2 When fitting the wall arm drill a suitable 19mm hole through the wall you may require a suitable piece of wood to give the arm support behind the tiles or plasterboard 3 Remove fittings and nuts from end of arm and push arm through wall re fit washer and nut 4 Connec...

Страница 11: ... isolation valve The water flow should fall to a very low flow possibly only a drip after a few seconds Collect the water after 5 seconds and 30 seconds and measure the temperature it should be below 46 C 2 C Turn on the cold water again and it should return after a few seconds to stabilise to 38 C 2 C Ensure that you instruct all users in the safe operation of the shower as outlined in this docum...

Страница 12: ...tlet at the same time A Running pressure in excess of maximum recommended A Flow control cartridge worn SUGGESTED ACTION Remove valve and clean filters Adjust temperature control Turn the temperature control anti clockwise Turn the temperature control anti clockwise Remove valve and clean filters on the inlet Make sure the hot water is available by trying a hot water tap elsewhere in the house Tur...

Страница 13: ...stration Card 1 Flow Controller 2 MX GROUP GUARANTEE Marleton Cross Limited and its subsidiaries MX Group hope you are satisfied with your purchase and in the unlikely event that you encounter a problem which is caused exclusively by MX Group manufactured product the product we will take responsibility on the terms set out here We guarantee this product in the following terms for a period of 5 yea...

Страница 14: ...installed at the same time 8 Thecostofroutinemaintenance adjustments overhaulmodificationsorlossordamage arising there from including the cost of repairing damage breakdown malfunction caused by corrosion furring pipe scaling limescale system debris or frost 9 Units purchased and installed other than in the United Kingdom LIMITATIONS 1 This guarantee lasts for a single continuous period of 5 years...

Страница 15: ...s damage or injury suffered or incurred by you and you will indemnify us fully against any claims made by third parties in respect of the goods or otherwise arising from the contract 3 Nothing contained in the contract will be treated as excluding or restricting any liability on our part for death or personal injury resulting from our negligence 4 Except as stated above and to the fullest extent p...

Страница 16: ...it The engineer will not be able to repair or replace or advise on parts or products not supplied as part of the product 4 A charge will be made in the event of a service call aborted by you but not by us or where a call under the terms of guarantee has been booked and failure is not related to product supplied by MX Group i e Scaling and furring incorrect water pressure or other plumbing problem ...

Отзывы: