9
13a
12
13b
Square Style
Round Style
FITTING THE DOUBLE INTERLOCK HOSE & HANDSET
1.
Connect one end of the double interlock hose to the outlet on the wall outlet,
(See Fig 10a & 10b) making sure that the sealing washer is in place.
2.
Pass the double interlock hose through the hose retaining ring the screw onto the
handset using the washer (See Fig 11a & 11b), carry out a leak test.
3.
MX provide an eco flow controller with every handset they sell. This reduces the flow
of water at high water pressures. If you require, fit between the handset & the hose.
NOTE: It is the conical end of the double interlock hose which grips into the handset height
adjuster. The handset will not fit in the height adjuster without the double interlock
hose attached.
WALL ARM FITTING
1.
Establish position of wall arm to suit users requirements (See Fig 12).
2.
When fitting the wall arm drill a suitable 19mm hole through the wall, you may require
a suitable piece of wood to give the arm support behind the tiles or plasterboard.
3.
Remove fittings and nuts from end of arm and push arm through wall, re-fit washer
and nut.
4.
Connect wall arm to the pipework installed from the valve.
5.
When attaching the fixed showerhead make sure the sealing washer is in place and
screw tight to seal the joint (See Fig 13a & 13b) again a flow controller can be fitted if
required.
6.
Pressure test to make sure there are no leaks before tiling.
NOTE: The fitting of these items should be carried out by a competent person.
10a
10b
11a
11b
Square Style
Round Style
Square Style
Round Style
MX Atmos Select 6752B 09_14_GF.indd 10
24/10/2014 14:56